Bone remodelling at the interface with implant – an effect of implant surface micro-structure
نویسنده
چکیده
Good integration of metallic implant as for example endoprosthesis with a bone determines its stability and durability. There are many biological, structural and mechanical factors affecting interactions between bone tissue and a surface of prosthesis. Among the mechanical parameters local stress and strain distributions play a crucial role. The loading conditions, shape and mechanical characteristics of endoprosthesis determine an overall stress distribution in a bone and associated effect of stress shielding. However concerning the local state at the interface which is to big extent responsible for cells activities, intracellular matrix synthesis, tissue differentiation and remodelling apart from the biocompatibility and biochemical factors a micro-structure of an implant surface and its local mechanical parameters play a key role in expected good integration of a prosthesis. In the present work the results of a preliminary study of mentioned here effects are discussed.
منابع مشابه
Evaluation of the Effect of Zirconia and Titanium Abutments on Microleakage of Implant-Abutment Interface Under Oblique Cyclic Loading In Vitro
Background and Aim: Oral bacteria can proliferate in the implant-abutment interface (IAI) and cause inflammation in the peri-implant tissues and adjacent bone. This study aimed to assess the effect of zirconia and titanium abutments on the microleakage of the IAI under oblique cyclic loading conditions. Materials and Methods: In this in-vitro study, 12 implant-abutment assemblies with zirconia...
متن کاملComparative Evaluation of Microleakage at the Interface of Titanium and Zirconium Abutments Following Oblique Cyclic Loading: An in vitro Study
Abstract Background and aim: Oral microbiota could proliferate the microspace between the implant and abutment, thereby cause inflammation in the peri-implant tissues and adjacent bone. This study aimed to investigate the effect of two types of abutments (zirconia and titanium) on microleakage at implant-abutment interface area under oblique cyclic loading in vitro. Materials and methods:In thi...
متن کاملCement-Implant Interface Fracture Failure by Crack Initiation Due to Interface Cavity Stress Concentration
Nowadays total joint replacements are widely used in the world, so in average 800,000 joint surgeries are done yearly only in Europe and North America. However implant loosening is and remains as the major issue of all implant failures and therefore causes revision surgery procedures. Studies and experiments have identified poor fixation of implants most likely is the main cause of long term im...
متن کاملImplants delivering bisphosphonate locally increase periprosthetic bone density in an osteoporotic sheep model. A pilot study.
It is a clinical challenge to obtain a sufficient orthopaedic implant fixation in weak osteoporotic bone. When the primary implant fixation is poor, micromotions occur at the bone-implant interface, activating osteoclasts, which leads to implant loosening. Bisphosphonate can be used to prevent the osteoclastic response, but when administered systemically its bioavailability is low and the time ...
متن کامل3D printed Ti6Al4V implant surface promotes bone maturation and retains a higher density of less aged osteocytes at the bone-implant interface.
UNLABELLED For load-bearing orthopaedic applications, metal implants having an interconnected pore structure exhibit the potential to facilitate bone ingrowth and the possibility for reducing the stiffness mismatch between the implant and bone, thus eliminating stress-shielding effects. 3D printed solid and macro-porous Ti6Al4V implants were evaluated after six-months healing in adult sheep fem...
متن کامل