Dynamic Contour Tonometry, Tono-Pen XL®, and Goldmann Applanation Tonometry in Comparison to Intracameral Intraocular Pressure (IOP) Measurements in Patients with Corneal Pathologies
نویسندگان
چکیده
Unspecified Posted at the Zurich Open Repository and Archive, University of Zurich ZORA URL: http://doi.org/10.5167/uzh-101903 Published Version Originally published at: Neuburger, M; Grosswendt, J; Lautebach, S; Maier, P; Birnbaum, F; Böhringer, D; Funk, J; Jordan, J F; Reinhard, T (2014). Dynamic Contour Tonometry, Tono-Pen XL®, and Goldmann Applanation Tonometry in Comparison to Intracameral Intraocular Pressure (IOP) Measurements in Patients with Corneal Pathologies. Open Ophthalmology Journal:46-55. Open Journal of Ophthalmology, 2014, 4, 46-55 Published Online May 2014 in SciRes. http://www.scirp.org/journal/ojoph http://dx.doi.org/10.4236/ojoph.2014.42009 How to cite this paper: Neuburger, M., et al. (2014) Dynamic Contour Tonometry, Tono-Pen XL®, and Goldmann Applanation Tonometry in Comparison to Intracameral Intraocular Pressure (IOP) Measurements in Patients with Corneal Pathologies. Open Journal of Ophthalmology, 4, 46-55. http://dx.doi.org/10.4236/ojoph.2014.42009 Dynamic Contour Tonometry, Tono-Pen XL®, and Goldmann Applanation Tonometry in Comparison to Intracameral Intraocular Pressure (IOP) Measurements in Patients with Corneal Pathologies Matthias Neuburger1, Juliane Großwendt1, Sonja Lautebach1, Philip Maier1, Florian Birnbaum1, Daniel Böhringer1, Jens Funk2, Jens Friedrich Jordan1, Thomas Reinhard1 Eye Center, Albert-Ludwigs-University, Freiburg, Germany University Eye Hospital, Zürich, Switzerland Email: [email protected] Received 13 March 2014; revised 15 April 2014; accepted 6 May 2014 Copyright © 2014 by authors and Scientific Research Publishing Inc. This work is licensed under the Creative Commons Attribution International License (CC BY). http://creativecommons.org/licenses/by/4.0/
منابع مشابه
Clinical comparison of the ProTon and Tono-Pen tonometers with the Goldmann applanation tonometer.
A clinical evaluation of a new electron ProTon tonometer was performed comparing the values of intraocular pressure (IOP) measured using this instrument with those determined by a similar instrument, Tono-Pen XL, and by Goldmann applanation tonometry. The mean IOP measured in 106 eyes with the ProTon tonometer was not significantly different from that determined with Goldmann applanation, while...
متن کاملTono-Pen determination of intraocular pressure in patients with band keratopathy or glued cornea.
AIMS To evaluate the intraocular pressure (IOP) measurements in patients with band keratopathy or glued corneas obtained from affected and non-affected areas. METHODS 15 patients with band keratopathy or glued corneas were prospectively recruited. When both eyes were affected, only the right eye was analysed. Tono-Pen readings of IOP were obtained sequentially from the affected and non-affect...
متن کاملThe influence of central corneal thickness and age on intraocular pressure measured by pneumotonometry, non-contact tonometry, the Tono-Pen XL, and Goldmann applanation tonometry.
AIMS To evaluate the influence of central corneal thickness (CCT) on intraocular pressure (IOP) measurements made with the Goldmann applanation tonometer (GAT), Tono-Pen XL, ocular blood flow tonograph (OBF), and Canon TX-10 non-contact tonometer (NCT). METHODS CCT was recorded for either eye (randomly selected) of each of 105 untreated patients with ocular hypertension and glaucoma attending...
متن کاملCorneal modulus and IOP measurements in canine eyes using Goldmann applanation tonometry and Tono-pen.
PURPOSE To experimentally examine the effect of corneal modulus on Goldmann applanation tonometry (GAT) and Tono-pen (Tono-pen XL, Reichert, Inc., Depew, NY) measurements of intraocular pressure (IOP) in a canine eye model. METHODS Twenty-one canine globes were recovered from healthy animals. IOP was controlled at 10, 15, 20, 30, and 40 mm Hg and measured by GAT and Tono-pen following standar...
متن کاملTono-Pen tonometry in normal and in post-keratoplasty eyes.
Oculab Tono-Pen tonometry was compared with Goldmann applanation tonometry in 82 eyes of 82 patients with normal corneas and in 54 eyes of 54 patients who had undergone penetrating keratoplasty and whose corneas did not preclude the use of Goldmann tonometer. We found that the intraocular pressure (IOP) in 48% of the eyes with normal corneas and in 57% after keratoplasty has different measureme...