High-Intensity Focused Ultrasound Circular Cyclocoagulation in Glaucoma: A Step Forward for Cyclodestruction?

نویسندگان

  • Rodolfo Mastropasqua
  • Vincenzo Fasanella
  • Alessandra Mastropasqua
  • Marco Ciancaglini
  • Luca Agnifili
چکیده

The ciliary body ablation is still considered as a last resort treatment to reduce the intraocular pressure (IOP) in uncontrolled glaucoma. Several ablation techniques have been proposed over the years, all presenting a high rate of complications, nonselectivity for the target organ, and unpredictable dose-effect relationship. These drawbacks limited the application of cyclodestructive procedures almost exclusively to refractory glaucoma. High-intensity focused ultrasound (HIFU), proposed in the early 1980s and later abandoned because of the complexity and side effects of the procedure, was recently reconsidered in a new approach to destroy the ciliary body. Ultrasound circular cyclocoagulation (UC3), by using miniaturized transducers embedded in a dedicated circular-shaped device, permits to selectively treat the ciliary body in a one-step, computer-assisted, and non-operator-dependent procedure. UC3 shows a high level of safety along with a predictable and sustained IOP reduction in patients with refractory glaucoma. Because of this, the indication of UC3 was recently extended also to naïve-to-surgery patients, thus reconsidering the role and timing of ciliary body ablation in the surgical management of glaucoma. This article provides a review of the most used cycloablative techniques with particular attention to UC3, summarizing the current knowledge about this procedure and future possible developments.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Cyclocoagulation of the ciliary bodies by high-intensity focused ultrasound: a 12-month multicenter study.

PURPOSE To evaluate the safety and efficacy of high-intensity focused ultrasound (HIFU) cyclocoagulation in reducing intraocular pressure (IOP) in patients with refractory glaucoma by using a novel miniaturized delivery device (EyeOP1). METHODS We conducted a 12-month open-label multicenter prospective study (EyeMUST1 Study). Patients with primary (primary open-angle glaucoma [POAG]) or secon...

متن کامل

High-intensity focused ultrasound treatment in refractory glaucoma patients: results at 1 year of prospective clinical study.

PURPOSE To evaluate the safety and efficacy of the ultrasonic circular cyclo-coagulation procedure using high-intensity focused ultrasound by a miniaturized annular device containing 6 piezoceramic transducers in patients with refractory glaucoma. METHODS This was a prospective interventional noncomparative study of 20 eyes of 20 patients with refractory glaucoma. All eyes were treated with 6...

متن کامل

Clinical Trials Cyclocoagulation of the Ciliary Bodies by High-Intensity Focused Ultrasound: A 12-Month Multicenter Study

Hôpital de la Croix-Rousse, Service d’Ophtalmologie, Hospices Civils de Lyon, Lyon, France Service d’Ophtalmologie, Centre Hospitalier Universitaire de Grenoble, Grenoble, France Service d’Ophtalmologie, Hôpital Claude Huriez, CHRU de Lille, Lille, France Service d’Ophtalmologie 3, Centre Hospitalier National des Quinze-Vingts, Paris, France Institut du Glaucome, Fondation Hôpital Saint-Joseph,...

متن کامل

Therapeutic effects of high intensity focused ultrasound for in patients with benign uterine tumors with regard to lifestyle and obstetric characteristics

Background: The present investigation compared the decrease in the volume of benign tumor before and after High Intensity Focused Ultrasound (HIFU) treatment to evaluate the therapeutic effects of HIFU. in terms of Lifestyle and obstetric characteristics of in patients with Benign Uterine Tumors. Materials and Methods: To collect the data on each patients’ lifestyle and obstetric characteristic...

متن کامل

Numerical Study for Optimizing Parameters of High-Intensity Focused Ultrasound-Induced Thermal Field during Liver Tumor Ablation: HIFU Simulator

Introduction High intensity focused ultrasound (HIFU) is considered a noninvasive and effective technique for tumor ablation. Frequency and acoustic power are the most effective parameters for temperature distribution and the extent of tissue damage. The aim of this study was to optimize the operating transducer parameters such as frequency and input power in order to acquire suitable temperatu...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 2017  شماره 

صفحات  -

تاریخ انتشار 2017