Force and pressure distribution using Macintosh and GlideScope laryngoscopes.
نویسندگان
چکیده
BACKGROUND The forces applied to the soft tissues of the upper airway may have a deleterious effect. This study was designed to evaluate the performance of the GlideScope compared with the Macintosh laryngoscope. METHODS Twenty anaesthetists and 20 trainees attempted tracheal intubation of a Laerdal SimMan manikin. Forces and pressure distribution applied by both laryngoscope blades onto the soft upper airway tissues were measured using film pressure transducers. The minimal force needed to achieve a successful intubation, in the same simulated scenario, was measured; additionally, we considered the visualization score achieved by using the Cormack-Lehane grades. RESULTS All participants applied, on average, lower force with the GlideScope than with the Macintosh in each simulated scenario. Forces [mean (sd)] applied in the normal airway scenario [anaesthetists: Macintosh 39 (22) N and GlideScope 27 (15) N; trainees: Macintosh 45 (24) N and GlideScope 21 (15) N] were lower than forces applied in the difficult airway scenario [anaesthetists: Macintosh 95 (22) N and GlideScope 66 (20) N; trainees: Macintosh 100 (38) N and GlideScope 48 (16) N]. All the intubations using the GlideScope were successful, regardless of the scenario and previous intubation experience. The average pressure on the blades was 0.13 MPa for the Macintosh and 0.07 MPa for the GlideScope, showing a higher uniformity for the latter. CONCLUSIONS The GlideScope allowed the participants to obtain a successful intubation applying a lower force. A flatter and more uniform pressure distribution, a higher successful rate, and a better glottic view were observed with the GlideScope.
منابع مشابه
CORRESPONDENCE Force and pressure distribution using Macintosh and GlideScope laryngoscopes
Force and pressure distribution using Macintosh and GlideScope laryngoscopes Editor—Carassiti and colleagues are to be commended for their work attempting to compare the forces applied to the airway during laryngoscopy with the Glidescope Cobalt and the Macintosh laryngoscope. However, one issue deserves comment, there is an important difference between the two blades that was not accounted for...
متن کاملمقایسه میزان موفقیت لوله گذاری تراشه بعد از آموزش با دو روش گلایدسکوپ و لارنگوسکوپ
Background: Tracheal intubation is one of the most essential skills employed by all healthcare providers, nevertheless novice intubators turn out to be less successful when they initially perform the intubation. Video- laryngoscopes (GlideScopes) are novel instruments able to increase the success rate of tracheal intubation training. The aim of this study was to compare the success rate of trac...
متن کاملComparison of the Glidescope® and Pentax AWS® laryngoscopes to the Macintosh laryngoscope for use by Advanced Paramedics in easy and simulated difficult intubation
BACKGROUND Intubation of the trachea in the pre-hospital setting may be lifesaving in severely ill and injured patients. However, tracheal intubation is frequently difficult to perform in this challenging environment, is associated with a lower success rate, and failed tracheal intubation constitutes an important cause of morbidity. Novel indirect laryngoscopes, such as the Glidescope and the A...
متن کاملComparison of the performance of four laryngoscopes in a high-fidelity simulator using normal and difficult airway.
BACKGROUND Novel laryngoscopes may demonstrate advantages over the traditional Macintosh laryngoscope for difficult airways. Our study compared Glidescope laryngoscope, Bonfils fibrescope, and CTrach intubating laryngeal mask airway with the Macintosh laryngoscope in a simulated normal and difficult airway, considering the additional effect of previous intubation experience. METHODS Twenty-tw...
متن کاملComparison of the McGrath® Series 5 and GlideScope® Ranger with the Macintosh laryngoscope by paramedics
BACKGROUND Out-of-hospital endotracheal intubation performed by paramedics using the Macintosh blade for direct laryngoscopy is associated with a high incidence of complications. The novel technique of video laryngoscopy has been shown to improve glottic view and intubation success in the operating room. The aim of this study was to compare glottic view, time of intubation and success rate of t...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- British journal of anaesthesia
دوره 108 4 شماره
صفحات -
تاریخ انتشار 2012