Lens density measurements by two independent psychophysical techniques

نویسندگان

  • Anirbaan Mukherjee
  • Richard A Bone
چکیده

BACKGROUND Cataract, a leading cause of vision impairment, is due to the lens becoming excessively optically dense. Change in the lens optical density (LOD) could be a useful indicator of incipient nuclear cataract and would necessitate the development of accurate measurement techniques. Mapcat sf™ is a heterochromatic flicker photometer for measuring macular pigment optical density (MPOD) under photopic conditions. In the process, it also measures LOD that is needed in the calculation of MPOD. LOD is then converted by the instrument to "lens equivalent age" (LEA). However, varying cone photoreceptor ratios among individuals could affect the LEA measurement. Scotopic vision is mediated by rod photoreceptors; therefore, LEA measurement under scotopic conditions potentially provides a reliable standard for assessing other methods. The study was conducted to test the level of agreement between the LEA data obtained under photopic and scotopic conditions for a sample population. We also comment on factors that might contribute to any disagreement. METHODS LEAs were obtained by Mapcat sf for 25 subjects and compared with those obtained under absolute scotopic threshold conditions. RESULTS The mean scotopic LEA for the subjects was 2.7 years higher than the mean photopic LEA, but this difference was not statistically significant. Measurements by the two methods were reasonably correlated (r(2) = 0.59, p < 0.0001). Significant individual differences in LEA by the two methods were found for six of the 25 subjects. Although our calculations included a standard long- to medium-wavelength-sensitive cone ratio, we found that different ratios could be found that rendered the differences in LEA insignificant for two of these six subjects. Variability in pupil diameter during scotopic measurements was considered another potential source of discrepancy between LEAs by the two methods. CONCLUSION The absolute threshold technique, with long adaptation times, is probably impractical for routine lens density measurement, whereas Mapcat sf provided a rapid, straightforward test that may find its application in optometric/ophthalmic practice.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Optical density of the human lens.

Optic disk reflectance was measured from 27 normal observers with their physiological lenses (aged 21-74 yr) and from two pseudophakic observers (aged 69 and 70 yr) with use of a Utrecht fundus reflection densitometer. Psychophysical heterochromatic flicker photometric luminance matches (10 degrees field) were obtained on the same group of the observers. A four-parameter model incorporating len...

متن کامل

Fundus reflectance and the measurement of crystalline lens density.

We have developed an optical technique for measuring the in vivo absorption of the human crystalline lens based on using the retina as a reflector for a double-pass measurement of lens density. We compare results obtained by the reflectometric technique with results obtained in the same subjects by a psychophysical method. We find that the estimates obtained with the two techniques are highly c...

متن کامل

Dosimetric comparison of two different whole brain radiotherapy techniques in patients with brain metastases: How to decrease lens dose?

Background: Palliative whole brain radiotherapy (WBRT) has been the standard treatment for brain metastases. Ionizing radiation is known to be one of the most potent cataractogenic agents. We aimed to evaluate two different radiotherapy techniques with respect to the doses received by the organs at risk (OAR) in patients with brain metastasis who undergone WBRT. Materials and Methods: Ten conse...

متن کامل

Method for in vitro assessment of straylight from intraocular lenses.

Ocular straylight has been measured by means of psychophysical methods over the years. This approach gives a functional parameter yielding a straight comparison with optically defined light scattering, and the point-spread-function. This is of particular importance when the effect of intraocular lenses (IOLs) on postoperative straylight is sought. An optical system for straylight measurements o...

متن کامل

A Determination of H0 with the CLASS Gravitational Lens B1608+656: III. A Significant Improvement in the Precision of the Time Delay Measurements

The gravitational lens CLASS B1608+656 is the only four-image lens system for which all three independent time delays have been measured. This makes the system an excellent candidate for a high-quality determination of H0 at cosmological distances. However, the original measurements of the time delays had large (12–20%) uncertainties, due to the low level of variability of the background source...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 3  شماره 

صفحات  -

تاریخ انتشار 2016