The influence of the number and the type of magnetic attachment on the retention of mandibular mini implant overdenture
نویسندگان
چکیده
PURPOSE The aim of this study was to compare the retention of mini implant overdenture by the number, the type of magnetic attachment, and the directions of applied dislodging force. MATERIALS AND METHODS The experimental groups were designed by the number and type of magnetic attachment. Twenty samples were tested with Magden implants. Each attachment was composed of the magnet assembly in overdenture sample and the abutment keeper in a mandibular model. Dislodging forces were applied to the overdenture samples (50.0 mm/min) in 3 directions. The loading was repeated 10 times in each direction. The values of dislodging force were analyzed statistically using SPSS at 95% level of confidence. RESULTS The retentive force of group 2 was greater than that of group 1 in both types of attachment in every direction (P < .05). Oblique retentive force of flat type magnetic attachment was higher than that of cushion type attachment in both groups (P < .05). In group 1, oblique retentive force showed the highest and anterior-posterior retentive force showed the lowest value in both attachment types (P < .05). In group 2, both types of attachment showed the lowest retentive force with anteriorposterior direction of dislodging force (P <.05). CONCLUSION Proper retentive properties for implant overdenture were obtained, regardless of the number and type of magnetic attachment. In both types of magnetic attachment, the greater retentive force was attained with more implants. Oblique retentive force of flat type magnetic attachment was greater than that of cushion type. Among all subgroups, anterior-posterior retentive force was the lowest among three different directions of dislodging force.
منابع مشابه
Comparison of the Effect of Ball and Bar Attachment Designs on Retention and Stability of Mandibular Implant-Supported Overdentures
Objectives: The present study evaluated the effect of bar and ball attachment designs on retention and stability of a mandibular overdenture supported by four implants. Methods: An edentulous mandibular acrylic resin model with four implants in the anterior part of the ridge (A, B, D and E) was fabricated. A metal framework simulating the overdenture was also fabricated. Totally, 30...
متن کاملEffect of Abutment Height Difference on Stress Distribution in Mandibular Overdentures: A Three-Dimensional Finite Element Analysis
Background and Aim: Implant-supported overdentures are a treatment option for edentulous patients. One of the important factors in determining the prognosis of overdenture treatment is to control the distribution of stress in the implant-bone and attachment complex. This study assessed the effect of implant abutment height difference on stress distribution in mandibular overdentures. Materials...
متن کاملDesign and Manufacturing of Titanium Attachment for Single Implant Retained Mandibular Overdenture: A Review
People loss their teeth due to numerous reason. These people have to go for dental treatment and get artificial teeth. But denture treatment is very costly for an average human with limited income. The main factor contributing to the cost of the denture is number of implants used for the treatment .A single implant cost around Rs. 25000 and generally for better stability dentist use two or more...
متن کاملEffect of Denture Cleansing Solutions on Retention of Two Types of Overdenture Attachments
Background and Aim: There is lack of information regarding the effect of different denture cleansing solutions on the retention of attachments. This study aimed to as-sess the effect of denture cleansing solutions on the retention of Dalbo-Plus and Loca-tor attachment systems. Materials and Methods: This study evaluated 160 attachments including 80 Locator and 80 Dalbo-Plus attachment systems....
متن کاملMaxillary Implant-Supported Over-Denture, Role of Attachment Selection on Treatment Success Rate: A Literature Review
Objectives Maxillary implant-supported over-denture is a suitable treatment where conventional denture cannot be used. Few studies are available on maxillary over-denture while more are available on mandibular over-denture with no literature referring to attachment selection in maxillary over-dentures. The objective of this literature review was to see attachment selection strategies in maxill...
متن کامل