BACKGROUND To describe management of a case of intraocular lens (IOL) and capsular bag (CB) dislocation in an eye with an Ahmed glaucoma valve in the posterior chamber. CASE PRESENTATION A 75-year-old pseudophakic man with open-angle glaucoma and diabetic retinopathy developed neovascular glaucoma. After two intravitreous injections of bevacizumab and panretinal photocoagulation were administered, the new vessels regressed. However, goniosynechiae were observed over 360° of the angle. An Ahmed glaucoma valve model FP7 was implanted with the tube in the posterior chamber with adequate intraocular pressure control. Nineteen years after cataract surgery, when the IOL-CB complex became dislocated, they were sutured transclerally to the sulcus without Ahmed glaucoma valve modification. After a coughing episode, the vitreous pushed the IOL-CB complex forward and the tube was behind the IOL-CB complex. A 25-gauge posterior vitrectomy was performed, and the tube was returned to in front of the optic of the IOL using a forceps tip through a sclerotomy. CONCLUSION This case suggested that management of IOL-CB dislocation can modify glaucoma shunt function. A complete pars plana vitrectomy may be required in order to reposition the dislocated IOL-CB complex in the presence of a posterior chamber drainage tube implant.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Inferior subconjunctival dislocation of posterior chamber intraocular lens after blunt trauma

Traumatic subconjunctival dislocation of the posterior chamber intraocular lens (PCIOL) is a rare and emergency condition. Here, we report an interesting variation of rare case of inferior subconjuctival dislocation of PCIOL in a 75-year-old female patient following blunt trauma to her right eye with cow's head. All the previous literature with subconjuctival dislocation of PCIOL has reported t...

متن کامل

Intralenticular Cilia Following Penetrating Ocular Trauma: A Case Report

Penetrating ocular trauma is one of the most important causes of vision loss, especially in men, and can be associated with intraocular foreign bodies. The incidence of intraocular cilia after trauma is very low. Here we report the case of a 24-year-old man who visited Poostchi Ophthalmology Clinic (Shiraz, Iran) due to a gradual vision loss in his left eye over the past 2 months. The probable ...

متن کامل

Late-Onset Anterior Dislocation of a Posterior Chamber Intraocular Lens in a Patient with Pseudoexfoliation Syndrome

Here, we report on a patient with pseudoexfoliation syndrome who developed acute angle-closure glaucoma with a marked myopic shift due to anterior dislocation of the posterior chamber intraocular lens almost 16 months after an uneventful phacoemulsification. Examination with a Scheimpflug camera was extremely useful in confirming the diagnosis. This is the fist case of late-onset angle-closure ...

متن کامل

[Pupillary block acute glaucoma due to acrylic intraocular lens posterior dislocation after Nd:YAG capsulotomy].

CASE REPORT We present the clinical case of a 68 year-old woman who developed a pupillary block acute glaucoma due to vitreous hernia into anterior chamber following posterior dislocation of the intraocular lens one month after an Nd:YAG capsulotomy. DISCUSSION We should consider these symptoms in the differential diagnosis of pseudophakic acute glaucoma, especially when visualisation of the ...

متن کامل

Posterior dislocation of an intraocular lens implant and its removal.

The cause of dislocation of an intraocular lens is a direct blow or jerk, and dislocation may complicate both iris-supported and capsule-supported lenses. In capsule-supported lenses the implant dislocates towards the anterior chamber but in iris-supported lenses the dislocation is posterior. A technique for removal of a posterity dislocated lens is described.