Minimax Emission Computed Tomography Using High-resolution Anatomical Side Information And B-spline - Information Theory, IEEE Transactions on

نویسندگان

  • Alfred O. Hero
  • Jeffrey A. Fessler
  • Steven R. Titus
چکیده

In this paper a minimax methodology is presented for combining information from two imaging modalities having different intrinsic spatial resolutions. The focus application is emission computed tomography (ECT), a low-resolution modality for reconstruction of radionuclide tracer density, when supplemented by high-resolution anatomical boundary information extracted from a magnetic resonance image (MRI) of the same imaging volume. The MRI boundary within the two-dimensional (2-D) slice of interest is parameterized by a closed planar curve. The Cramèr–Rao (CR) lower bound is used to analyze estimation errors for different boundary shapes. Under a spatially inhomogeneous Gibbs field model for the tracer density a representation for the minimax MRI-enhanced tracer density estimator is obtained. It is shown that the estimator is asymptotically equivalent to a penalized maximum likelihood (PML) estimator with resolutionselective Gibbs penalty. Quantitative comparisons are presented using the iterative space alternating generalized expectation maximization (SAGE-EM) algorithm to implement the PML estimator with and without minimax weight averaging.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Minimax Emission Computed Tomography using High-Resolution Anatomical Side Information and B-Spline Models

In this paper a minimax methodology is presented for combining information from two imaging modalities having different intrinsic spatial resolutions. The focus application is emission computed tomography (ECT), a low-resolution modality for reconstruction of radionuclide tracer density, when supplemented by high-resolution anatomical boundary information extracted from a magnetic resonance ima...

متن کامل

REVISION OF SUBMISSION TO IEEE TRANSACTIONS ON INFORMATION THEORY , 1998 1 Minimax Emission Computed Tomography using High ResolutionAnatomical Side

In this paper a minimax methodology is presented for combining information from two imaging modalities having diierent intrinsic spatial resolutions. The focus application is emission computed tomography (ECT), a low resolution modality for reconstruction of radionuclide tracer density, when supplemented by high resolution anatomical boundary information extracted from a magnetic resonance imag...

متن کامل

Theory and Implementation of Minimax Ect Image Reconstruction with Mri Side Information

In this report a minimax methodology is presented for combining information from two imaging modalities having diierent intrinsic spatial resolutions. The focus application is emission computed tomography (ECT), a low resolution modality for reconstruction of radionuclide tracer density, when supplemented by high resolution anatomical boundary information extracted from a magnetic resonance ima...

متن کامل

Bayesian reconstruction and use of anatomical a priori information for emission tomography

A Bayesian method is presented for simultaneously segmenting and reconstructing emission computed tomography (ECT) images and for incorporating high-resolution, anatomical information into those reconstructions. The anatomical information is often available from other imaging modalities such as computed tomography (CT) or magnetic resonance imaging (MRI). The Bayesian procedure models the ECT r...

متن کامل

Information analysis of single photon emission computed tomography with count losses.

An analysis is presented of the information transfer from emitter-space to detector-space in single photon emission computed tomography (SPECT) systems. The analysis takes into account the fact that count loss side information is generally not available at the detector. Side information corresponds to the number gamma-rays lost deleted due to lack of interaction with the detector data. It is sh...