Volumetric‐modulated arc therapy versus intensity‐modulated radiotherapy for large volume retroperitoneal sarcomas: A comparative analysis of dosimetric and treatment delivery parameters
نویسندگان
چکیده
PURPOSE To compare dosimetric and treatment delivery parameter differences between volumetric-modulated arc radiotherapy (VMAT) and intensity-modulated radiotherapy (IMRT) for large volume retroperitoneal sarcomas (RPS). MATERIALS AND METHODS Both VMAT and IMRT planning were performed on CT datasets of 10 patients with RPS who had been previously treated with preoperative radiotherapy. Plans were optimized to deliver ≥95% dose to the PTV and were evaluated for conformity and homogeneity. Dose to the organs at risk (OARs) (kidney, liver, spinal cord, and bowel space), unspecified tissue, and dose evaluation volumes (DEVs) at 1, 2, and 5 cm from PTV were calculated and compared. Monitor units (MUs) and treatment delivery times were recorded and compared between the two techniques. The deliverability of the large volume RPS VMAT plans was verified by portal dosimetry on a Truebeam™ linac. RESULTS VMAT and IMRT plans were equivalent for PTV coverage and homogeneity (P > 0.05); however, VMAT plans had slightly better conformity index, CI (P < 0.001). Doses to the OARs were not significantly different between VMAT and IMRT plans (P > 0.05). Mean doses to the unspecified tissue as well as at 1, 2, and 5 cm DEVs were lower with VMAT compared with IMRT, P = 0.04 and P < 0.01, respectively. MUs and average beam-on times were both significantly lower in the VMAT vs IMRT plans, P < 0.001 and P = 0.001, respectively. All VMAT plans passed portal dosimetry delivery verification with an average gamma passing rate of 99.6 ± 0.4%. CONCLUSIONS VMAT planning for large volume RPS improved CI, and achieved comparable OAR sparing, as compared with IMRT. As treatment delivery time was lower, the use of VMAT for RPS may translate into improved treatment delivery efficiency.
منابع مشابه
Dosimetric Evaluation of Volumetric Modulated Arc Therapy (VMAT) and Intensity Modulated Radiotherapy (IMRT) Using AAPM TG 119 Protocol
Background: The commissioning accuracy of Volumetric Modulated Arc Therapy (VMAT) need to be evaluated.Objective: To test and evaluate commissioning accuracy of VMAT based on the TG 119 protocols at local institution. Material and Methods: The phantom, structure sets, VMAT and IMRT beam parameter setup, dose prescriptions and planning objectives were following TG 119 guidelines to c...
متن کاملVolumetric modulated arc therapy versus step-and-shoot intensity modulated radiation therapy in the treatment of large nerve perineural spread to the skull base: a comparative dosimetric planning study
INTRODUCTION Cutaneous squamous cell carcinoma with large nerve perineural (LNPN) infiltration of the base of skull is a radiotherapeutic challenge given the complex target volumes to nearby organs at risk (OAR). A comparative planning study was undertaken to evaluate dosimetric differences between volumetric modulated arc therapy (VMAT) versus intensity modulated radiation therapy (IMRT) in th...
متن کاملDosimetric Comparison and Evaluation of 4 Stereotactic Body Radiotherapy Techniques for the Treatment of Prostate Cancer
PURPOSE The aim of this study was to compare dosimetric characteristics, monitor unit, and delivery efficiency of 4 different stereotactic body radiotherapy techniques for the treatment of prostate cancer. METHODS This study included 8 patients with localized prostate cancer. Dosimetric assets of 4 delivery techniques for stereotactic body radiotherapy were evaluated: robotic CyberKnife, nonc...
متن کاملQuantification and modelling of the dosimetric impact of the treatment couch in volumetric modulated arc therapy (VMAT)
Background: As the volumetric modulated arc therapy (VMAT) becoming a main role of treatment ways, the effect of couch top becomes more significant. It is imperative to re-evaluate the couches that previously may have been considered of no importance during early treatment techniques. The impact of couch top on radiation delivery was explored and the couch model was tested with the aim of reduc...
متن کاملComparison of Volumetric Modulated Arc Therapy and Three-Dimensional Conformal Radiotherapy in Postoperative High-Grade Glioma: A Dosimetric Comparison
Introduction: We aimed to dosimetrically compare three-dimensional conformal radiotherapy (3D-CRT) and volumetric modulated arc therapy (VMAT) in terms of planning target volume (PTV) coverage, organ at risk (OAR) sparing, and conformity index (CI). Material and Methods: Planning data of 26 high grade glioma (HGG) patients were used. Prescrib...
متن کامل