Effect of albumin concentration on the assay of serum free thyroxin by equilibrium radioimmunoassay with labeled thyroxin analog (Amerlex Free T4).
نویسندگان
چکیده
Serum free thyroxin (FT4) in normal nonpregnant and pregnant subjects was measured by radioimmunoassay (RIA) with Amerlex FT4 RIA (Amersham International) and LiquiSol FT4 RIA (Damon Diagnostics) kits. Amerlex FT4 values in serum from pregnant women were lower than those in serum from nonpregnant women, but LiquiSol FT4 values were similar in serum from both groups. Amerlex FT4 values were directly correlated with the concentrations of albumin in serum and inversely correlated with those of thyroxin-binding globulin, but not with prealbumin concentrations. No significant correlations were observed between LiquiSol FT4 values and serum concentrations of thyroxin-binding proteins. Amerlex FT4 values were normal in patients with excess, deficient, or decreased thyroxin-binding globulin. Albumin added to serum samples increased Amerlex FT4 values but not LiquiSol FT4 values. Albumin inhibited the binding of labeled thyroxin analog to the solid-phase thyroxin antibody. These data indicate that the albumin concentration influences FT4 values as measured by an RIA involving a thyroxin analog and that Amerlex FT4 values should be carefully interpreted when the patient has an abnormal concentration of serum albumin.
منابع مشابه
Effect of detergent on triglyceride assay.
2. Meinhold H, Wenzel KW. Comparative methodological studies with six commercial FF4 kits. Nucl Compact 1985;16:317-20. 3. Ross HA. An indirect assay for serum free thyroxin (FF4) using monoclonal antibody coated tubes and radiolabeled thyroxin. Ibid., 1985;32:314-6. 4. Stockigt JR, Stevens V, White EL, Barlow JW. “Unbound analog” radioimmunoassays for free thyroxin measure the albuminbound hor...
متن کاملElectroimmunoassay of prealbumin in cerebrospinal fluid.
10. Amino N, Nishi K, Nakatani K, et al. Effect of albumin concentration on the assay of serum free thyroxin by equilibrium radioimmunoassay with labeled thyroxin analog (Amerlex#{174} F’reeT4). Clin C/tern 29, 321-325 (1983). 11. Stockigt JR, Stevens V, White EL, Barlow JW. “Unbound analog” radioimmunoassay methods for free thyroxin measure the albumin-bound hormone fraction. Clin C/tern 29, 1...
متن کاملComprehensive study of a thyroxin-analog-based assay for free thyroxin ("Amerlex FT4").
The basic theory of thyroxin-analog-based radioimmunoassays for free thyroxin has been extended to evaluate definitively the effects arising from residual binding of the tracer analog to serum proteins. Using experimentally determined binding constants and computer simulation techniques, we studied the effects of thyroxin-analog binding to serum proteins on results of Amerlex FT4 radioimmunoass...
متن کاملEvaluation of a new free-thyroxin assay.
The Amerlex Free Thyroxin (T4) Radioimmunoassay Kit (Amersham International Ltd.) is a new direct equilibrium radioimmunoassay for free T4 based on an antiserum with very high affinity for T4, and a unique 125I-labeled T4 analog as tracer. It is a very simple single-tube radioimmunoassay, making use of Amerlex particles to separate antibody-bound from free species. Interassay precision (CV) is ...
متن کاملOn the albumin dependence of measurements of free thyroxin. I. Technical performance of seven methods.
We evaluated three one-step (analog) and two two-step radioimmunoassay for free thyroxin (FT4), and a FT4 index calculated from the total T4 (TT4) and thyroxin-binding globulin (TBG) ratio for technical performance, for correlation with the reference FT4 method (equilibrium dialysis), and for dependence on TBG and albumin concentrations. The one-step methods (Amerlex, Coat-A-Count, and GammaCoa...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Clinical chemistry
دوره 29 2 شماره
صفحات -
تاریخ انتشار 1983