Dynamic Correction for Parallel Conductance , GP , and 1 Gain Factor , α , in Invasive Murine Left Ventricular 2 Volume Measurements
نویسندگان
چکیده
The conductance catheter technique could be improved by determining instantaneous parallel 40 conductance (GP) which is known to be time-varying, and by including a time-varying calibration factor in 41 Baan’s equation (α(t)). We have recently proposed solutions to the problems of both time-varying GP and time42 varying α, which we term “admittance” and “Wei’s equation”, respectively. We validate both our solutions in 43 mice, compared to the currently accepted methods, hypertonic saline (HS) to determine GP and Baan’s equation 44 calibrated with both stroke volume (SV) and cuvette. We performed simultaneous echocardiography in closed 45 chest mice (n=8) as a reference for left ventricular (LV) volume, and demonstrate that an off-center position for 46 the miniaturized Pressure-Volume (PV) catheter in the LV generates end-systolic and diastolic volumes 47 calculated by admittance with less error (p<0.03) (-2.49±15.33 μl error) compared to those same parameters 48 calculated by SV calibrated conductance (35.89±73.22 μl error), and by cuvette calibrated conductance 49 (-7.53±16.23 μl ES and -29.10±31.53 μl ED error). To utilize the admittance approach, myocardial permittivity 50 (εm) and conductivity (σm) were calculated in additional mice (n=7) and those results are used in this 51 calculation. In aortic banded mice (n=6) increased myocardial permittivity was measured (11844±2700 control, 52 21267±8005 banded, p<0.05), demonstrating that muscle properties vary with disease state. Volume error 53 calculated with respect to echo did not significantly change in aortic banded mice (6.74±13.06 μl, p=NS). 54 Increased inotropy in response to iv dobutamine was detected with greater sensitivity with the admittance 55 technique compared to traditional conductance (4.9±1.4 to 12.5±6.6 mmHg⋅μl Wei’s equation (p<0.05), 56 3.3±1.2 to 8.8±5.1 mmHg⋅μl using Baan’s equation (p=NS). New theory and method for instantaneous GP 57 removal, as well as application of Wei’s equation, are presented and validated in vivo in mice. We conclude that 58 for closed-chest mice, admittance (dynamic GP) and Wei’s equation (dynamic α) provide more accurate 59 volumes than traditional conductance, are more sensitive to inotropic changes, eliminate the need for hypertonic 60 saline, and can be accurately extended to aortic banded mice. 61 62 by 10.0.33.5 on O cber 0, 2017 http://jaysiology.org/ D ow nladed fom Dynamic GP and α Correction 3
منابع مشابه
Dynamic correction for parallel conductance, GP, and gain factor, alpha, in invasive murine left ventricular volume measurements.
The conductance catheter technique could be improved by determining instantaneous parallel conductance (G(P)), which is known to be time varying, and by including a time-varying calibration factor in Baan's equation [alpha(t)]. We have recently proposed solutions to the problems of both time-varying G(P) and time-varying alpha, which we term "admittance" and "Wei's equation," respectively. We v...
متن کاملCalibrating volume measurements made using the dual-field conductance catheter
The conductance catheter technique allows realtime measurements of ventricular volume based on changes in the electrical conductance of blood within the ventricular cavity. Conductance volume measurements are corrected with a calibration coefficient, α, in order to improve accuracy. However, conductance volume measurements are also affected by parallel conductance, which may confound calibratio...
متن کاملThe volume-dependency of parallel conductance throughout the cardiac cycle and its consequence for volume estimation of the left ventricle in patients.
OBJECTIVE To study the hypothesis that the electrical conductance of tissues and fluids (parallel conductance (G(p))) around the ventricle depends on left ventricular volume throughout the cardiac cycle. METHODS We extended a recently developed method to determine G(p) throughout the cardiac cycle. First, we compared the estimates of parallel conductances obtained with the new method (G(a)(p)...
متن کاملConductance, admittance, and hypertonic saline: should we take ventricular volume measurements with a grain of salt?
UNDOUBTEDLY THE MOST COMPREHENSIVE way to assess contractile function of the heart relies on pressure-volume relationships, often called pressure-volume loops. Originally established in the canine model by Sagawa and coworkers, pressure-volume relationships allow us to determine indexes of ventricular performance that are independent of loading conditions and heart rate such as preload-recruita...
متن کاملLeft ventricular volume measurement in mice by conductance catheter: evaluation and optimization of calibration.
The conductance catheter (CC) allows thorough evaluation of cardiac function because it simultaneously provides measurements of pressure and volume. Calibration of the volume signal remains challenging. With different calibration techniques, in vivo left ventricular volumes (V(CC)) were measured in mice (n = 52) with a Millar CC (SPR-839) and compared with MRI-derived volumes (V(MRI)). Signific...