Pulsed neodymium-YAG laser trabeculotomy: energy requirements and replicability.
نویسندگان
چکیده
Short pulsed laser trabeculotomy has been shown to reduce intraocular pressure in patients with primary open angle glaucoma. This study seeks to determine the energy levels required to produce a fistula into the canal of Schlemm for four different Q-switched neodymium-YAG lasers. The laser was fired at fixed human trabecular meshwork specimens at a range of energy settings for each laser and the characteristics and replicability of the lesions produced were analysed. Energy levels between 3 and 5 mJ were sufficient to produce fistulae into the canal of Schlemm with an approximately 50% success rate for each instrument.
منابع مشابه
Parameters for neodymium-YAG laser trabeculotomy: an in-vitro study.
A Biophysic Médical Nanolas Q-Switched pulsed neodymium-YAG laser has been used to produce lesions in human trabecular meshwork in vitro. Sectors of corneoscleral tissue containing trabecular meshwork were suspended in a waterbath which had had a Trokel gonioscopic contact lens mounted into one side by means of a watertight seal. The laser was used to produce lesions in the trabecular meshwork ...
متن کاملneodymium/YAG laser trabeculotomy
Laser trabeculotomies produced by directing a pulsed neodymium/YAG laser beam at specimens of human anterior chamber angle obtained post mortem or after enucleation were studied by light microscopy and by scanning and transmission electron microscopy to assess the dimensions of the openings created in the trabecular meshwork, their penetrance to the canal of Schlemm, and the extent or absence o...
متن کاملShort-pulsed neodymium-YAG laser trabeculotomy. An in vivo morphological study in the human eye.
The in vivo response to short-pulsed Nd-YAG laser damage to the trabecular meshwork has not been studied in the human eye. The nature of the response will determine the potential efficacy of this treatment for glaucoma. We have investigated short-pulsed laser trabeculotomy lesions created in the trabecular meshwork of four human eyes within 18 hr prior to enucleation for intraocular melanoma. S...
متن کاملIn vitro studies with a pulsed neodymium/YAG laser.
The relationships between the destructive effects of Q-switched Nd/YAG laser pulses and a number of experimental parameters were studied for various target materials including in particular excised, fixed samples of human trabecular meshwork. The laser parameters altered were the pulse energy, the convergence angle of the focused beam, and the position of the focus of the beam relative to the t...
متن کاملInfluence of shielding gas composition on weld structure in pulsed Nd: YAG laser welding
This work studied the effect of additions of carbon dioxide to argon shielding gas on the weld shape and microstructure of ST14 steel in pulsed Nd: YAG laser welding. By additions of carbon dioxide up to 15%,the weld area and depth/width ratio decreases while rising of carbon dioxide up to 25% causes increasing of weld area and depth/width ratio. It is observed that the weld metal microstructur...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The British journal of ophthalmology
دوره 73 3 شماره
صفحات -