Comparison of mucosal pressures induced by cuffs of different airway devices.
نویسندگان
چکیده
BACKGROUND High pressures exerted by balloons and cuffs of conventional endotracheal tubes, the Combitube (Tyco Healthcare Nellcor Mallinckrodt, Pleasanton, CA), the EasyTube (Teleflex Ruesch, Kernen, Germany), the Laryngeal Mask Airway (LMA North America, San Diego, CA), the Intubating Laryngeal Mask Airway (Fastrach; LMA North America), the ProSeal (LMA North America), and the Laryngeal Tube (LT; VBM Medizintechnik, Sulz, Germany) may traumatize the pharyngeal mucosa. The aim of this study was to compare pressures exerted on the pharyngeal, tracheal, and esophageal mucosa by different devices designed for securing the patient's airways. METHODS Nineteen fresh cadavers were included. To measure mucosal pressures, microchip sensors were fixed on the anterior, lateral, and posterior surfaces of the proximal balloon and the distal cuff of the investigated devices. Depending on the respective airway device, the cuff volume was increased in 10-ml increments at the proximal balloon starting from 0 to a maximum of 100 ml, and in 2-ml increments at the distal cuff starting from 0 up to 12 ml. RESULTS Tracheal mucosal pressures were significantly higher using the Combitube compared with the endotracheal tube and the EasyTube. Maximal esophageal pressures were significantly higher using the EasyTube compared with the Combitube. Using cuff volumes according to the manufacturers' guidelines, we found the highest pharyngeal pressures with the Intubating Laryngeal Mask Airway versus all other devices. At maximal volumes, the Laryngeal Mask Airway, the Intubating Laryngeal Mask Airway, and the ProSeal induced significantly higher pharyngeal pressures compared with all other devices. Using a pharyngeal cuff volume of 40 ml, the Intubating Laryngeal Mask Airway followed by the Laryngeal Mask Airway exerted significantly higher pressures compared with the other devices. CONCLUSIONS Although some devices exhibit a somewhat higher mucosal pressure when compared with others, the authors believe that the observed differences of the cuff pressures do not suggest a clinically relevant danger, because the investigated devices, except the endotracheal tubes, are not intended for prolonged use.
منابع مشابه
Endotracheal tube and laryngeal mask airway cuff pressures can exceed critical values during ascent to higher altitude.
OBJECTIVES Tracheal mucosal perfusion is compromised at an endotracheal tube (ETT) cuff pressure of 30 cm H(2)O, and blood flow is obstructed at a pressure of 50 cm H(2)O. METHODS We measured the change in pressure of air-filled cuffs of 6.0 and 7.5 ETTs and a size 4 laryngeal mask airway (LMA) from sea level to 2400 m. The ETTs and LMA cuff measurements were done with the devices uncontained...
متن کاملHigh-volume, low-pressure cuffs. Are they always low pressure?
Ischemic tracheal complications due to the ETT cuff occur in approximately 10 percent of mechanically ventilated critically ill patients despite the use of high-volume, low-pressure ETT cuffs. Using a laboratory model, we studied the effects of airway pressure on three different ETT cuff designs, including two "low pressure" designs. Positive airway pressure acted on the "low pressure" cuffs to...
متن کاملComparative evaluation of LMA-Supreme and i-gel supraglottic airway devices with endotracheal intubation during surgical correction of traumatic orbital injuries
Aims. The aim of the study was to compare endotracheal intubation with i-gel and LMA (laryngeal mask airway) supreme supraglottic airway devices in orbital osteosynthesis surgery. Methods. 134 patients undergoing orbital plasty after fracture were enrolled in our study and were randomized into three groups: 43 in the endotracheal intubation group, 42 in the LMA-Supreme group, and 49 patients w...
متن کاملThe Professional Experience of Anaesthesiologists in Proper Inflation of Laryngeal Mask and Endotracheal Tube Cuff.
OBJECTIVE Cuffs inflated to inappropriately high pressures cause ischemia, reducing tracheal mucosal blood flow, while cuffs inflated at lower pressure than necessary give rise to inadequate ventilation, aspiration of gastric contents, or extubation due to air leakage. In this study, we aimed to investigate the effect of the experience of anaesthesia staff on endotracheal tube and laryngeal mas...
متن کاملRapid pressure compensation by automated cuff pressure controllers worsens sealing in tracheal tubes.
BACKGROUND Cyclic redistribution of air within the cuff during respiratory pressure changes creates a self-sealing mechanism which allows tracheal sealing, despite tracheal airway pressure being above baseline cuff inflation pressure. The aim of the present study was to investigate the effect of continuous automated cuff pressure regulation on tracheal sealing during cyclic respiratory pressure...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Anesthesiology
دوره 104 5 شماره
صفحات -
تاریخ انتشار 2006