Study of nuclear cataract progression using the National Eye Institute Scheimpflug system.

نویسندگان

  • M B Datiles
  • B V Magno
  • V Freidlin
چکیده

AIMS A study was conducted to determine the capability of the recently developed National Eye Institute (NEI) Scheimpflug cataract imaging system in detecting changes in the nuclear region of the lens over a 1 year period. METHODS Twenty five eyes with pure nuclear cataracts with mean nuclear densities < or = 0.30 optical density units (ODU) as well as 30 normal control eyes were each examined at baseline and 12 months later. Computerised densitometry using the NEI Scheimpflug cataract imaging system was performed. Clinical grading of the lenses was also done using the Lens Opacities Classification System II (LOCS II). For densitometry, a change of plus or minus 0.023 ODU (the 99% range) in mean density in the nuclear area was considered a progression or regression at 1 year. RESULTS Using the Scheimpflug densitometry, 14 of the 25 cataractous eyes showed significant progression at 1 year. In the normal control group, only three of the 30 eyes showed significant progression. In contrast, using the LOCS II clinical grading, only two of the 25 cataractous eyes showed a one step increase, two of the 30 controls progressed at 1 year, and none regressed. There was no significant difference in visual acuity. CONCLUSION This study suggests the value of the NEI Scheimpflug cataract imaging system in detecting nuclear change within 1 year. However, clinically significant changes may require longer follow up periods. These data will be useful in planning future longitudinal studies of nuclear cataracts, such as for clinical trials of anticataract drugs.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Reproducibility of the NEI Scheimpflug Cataract Imaging System.

PURPOSE The NEI Scheimpflug Cataract Imaging System was developed to allow for easy, accurate and reproducible image analysis of nuclear cataracts. This study was undertaken to determine the reproducibility of densitometric measurements of the lens nucleus using this modified system. METHODS Replicate Zeiss Scheimpflug images of the lenses in 143 eyes were obtained by one photographer. Normal...

متن کامل

Comparative analysis of the nuclear lens opalescence by the Lens Opacities Classification System III with nuclear density values provided by Oculus Pentacam: a cross-section study using Pentacam Nucleus Staging software.

PURPOSE To compare the clinical classification of cataract using the Lens Opacities Classification System (LOCS) III with the mean values of lens density provided by the Pentacam Scheimpflug System in nuclear cataracts. METHODS One hundred and one eyes from 101 patients with age-related nuclear cataract were submitted to clinical examination for lens grading score using LOCS III. According to...

متن کامل

Accuracy of Scheimpflug Holladay equivalent keratometry readings after corneal refractive surgery.

PURPOSE To determine the accuracy of Pentacam Scheimpflug system Holladay equivalent keratometry (K) readings (EKRs) in calculating intraocular lens (IOL) power after corneal refractive surgery, including laser in situ keratomileusis (LASIK), photorefractive keratectomy (PRK), and radial keratotomy (RK). SETTING Jules Stein Eye Institute, David Geffen School of Medicine at University of Calif...

متن کامل

Quantitating nuclear opacification in color Scheimpflug photographs.

PURPOSE To test the validity of the color component subtraction method, a new objective technique of measuring nuclear cataract, and to correlate the tangent values of the different degrees of nuclear opacities to their corresponding subjective nuclear cataract grading using the Lens Opacities Classification System II and to another objective method of measuring nuclear cataract. METHODS Dens...

متن کامل

Scheimpflug lens densitometry and ocular wavefront aberrations in patients with mild nuclear cataract.

PURPOSE To test correlations between Scheimpflug optical densitometry and ocular higher-order aberrations (HOAs) in patients with mild nuclear cataract. SETTING Cornea and Refractive Surgery Department, Hospital de Braga, Braga, Portugal. DESIGN Retrospective single-center study. METHODS In eyes with mild nuclear cataract, lens densitometry was evaluated by Scheimpflug imaging (Pentacam H...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The British journal of ophthalmology

دوره 79 6  شماره 

صفحات  -

تاریخ انتشار 1995