Electrical resistance of a capillary endothelium

نویسندگان

  • C Crone
  • O Christensen
چکیده

The electrical resistance of consecutive segments of capillaries has been determined by a method in which the microvessels were treated as a leaky, infinite cable. A two-dimensional analytical model to describe the potential field in response to intracapillary current injection was formulated. The model allowed determination of the electrical resistance from four sets of data: the capillary radius, the capillary length constant, the length constant in the mesentery perpendicular to the capillary, and the relative potential drop across the capillary wall. Of particular importance were the mesothelial membranes covering the mesenteric capillaries with resistances several times higher than that of the capillary endothelium. 27 frog mesenteric capillaries were characterized. The average resistance of the endothelium was 1.85 omega cm2, which compares well with earlier determinations of the ionic permeability of such capillaries. However, heterogeneity with respect to resistance was observed, that of 10 arterial capillaries being 3.0 omega cm2 as compared with 0.95 omega cm2 for 17 mid- and venous capillaries. The average in situ length constant was 99 micrometers for the arterial capillaries and 57 micrometers for the mid- and venous capillaries. It is likely that the ions that carry the current must move paracellularly, through junctions that are leaky to small solutes.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Colorimetric assay to quantify macromolecule diffusion across endothelial monolayers.

Endothelial "capillary leak", the loss of vascular integrity in response to noxious stimuli, is characterized by extravasation of protein-richfluidfrom capillary lumen into surrounding tissue interstitium. This increase in vascular permeability, in response to inflammatory mediators, correlates with endothelial cell contraction and the formation of intercellular gaps within the monolayer. Howev...

متن کامل

Endothelial Transcytosis of Insulin: Does It Contribute to Insulin Resistance?

Most research on insulin resistance has focused on impaired signaling at the level of target tissues like skeletal muscle. Insulin delivery is also important and includes recruitment and perfusion of capillaries bearing insulin, but also the transit of insulin across the capillary endothelium. The mechanisms of this second stage (insulin transcytosis) and whether it contributes to insulin resis...

متن کامل

Optimum driving a Z-pinch for soft X-Ray lasers

A capillary plasma z-pinch as an alternative active medium of soft X-Ray lasers was studied experimentally and theoretically. The theoretical analysis was based on the self consistent solution of the so called “snow plow” model. The dynamics of pinched plasma is determined by the capillary parameters and by the time dependence of electrical current passing through it. The current time dependenc...

متن کامل

Effects of hyperthermia on cell survival and patterns of protein synthesis in endothelial cells from different origins.

Thermotolerance, transient resistance to heat induced by heat itself, is generally thought to be linked to the accumulation of heat-shock proteins in eukaryotic cells. The induction of thermotolerance and the synthesis of heat-shock proteins in primary and passage cultures of bovine aortic endothelium, passage cultures of bovine brain capillaries, and passage cultures of rat epididymal capillar...

متن کامل

A Biomechanical Approach for the Study of Deformation of Red Cells in Narrow Capillaries

This model focuses on the behavior of capillary-tissue fluid exchange system when the diameter of the capillary is less than that of red cell. In vivo and in vitro observations indicate that the width of the gap between the red cell and the vessel wall is generally small compared to the radius of the capillary for a single file flow of red cell in narrow vessel, particularly if the vessel diame...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Journal of General Physiology

دوره 77  شماره 

صفحات  -

تاریخ انتشار 1981