A geometric morphometric assessment of the optic cup in glaucoma.

نویسندگان

  • Paul G Sanfilippo
  • Andrea Cardini
  • Ian A Sigal
  • Jonathan B Ruddle
  • Brian E Chua
  • Alex W Hewitt
  • David A Mackey
چکیده

The morphologic appearance of the optic disc is of interest in glaucoma. In contrast to descriptive classification systems that are currently used, a quantitative approach to the analysis of optic disc morphology is required. Our goal was to determine the optimal method for quantifying optic cup shape by comparing traditional (ovality, form-factor and neuroretinal rim (NRR) width ratio) and geometric morphometric approaches. Left optic disc stereophotographs of 160 (80 normal and 80 glaucomatous (stratified by severity)) subjects were examined. The optic cup margins were stereoscopically delineated with a custom tracing system and saved as a series of discrete points. The geometric morphometric methods of elliptic Fourier analysis (EFA) and sliding semi-landmark analysis (SSLA) were used to eliminate variation unrelated to shape (e.g. size) and yield a series of shape variables. Differences in optic cup shape between normal and glaucoma groups were investigated. Discriminant functions were computed and the sensitivity and specificity of each technique determined. Receiver operator characteristic (ROC) curves were calculated for all methods and evaluated in their potential to discriminate between normal and glaucomatous eyes based on the shape variables. All geometric morphometric methods revealed differences between normal and glaucomatous eyes in optic cup shape, in addition to the traditional parameters of ovality, form-factor and NRR width ratio (p<0.0005). SSLA (minimum bending energy criterion--18 points) had the best sensitivity (83%) and area under the curve (AUC) (0.91). EFA (72 points) performed similarly well (74%, 0.89) as did the set of traditional shape-based variables (76%, 0.86). This study demonstrated that a geometric morphometric approach for discriminating between normal and glaucomatous eyes in optic cup shape is superior to that provided by traditional single parameter shape measures. Such analytical techniques could be incorporated into future automated optic disc screening modalities.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Optic Disc and Optic Cup Segmentation for Glaucoma Detection

Glaucoma is an eye disease that leads to vision loss. The symptoms of the glaucoma occurs when disease is quite advance. Glaucoma is called ‘silent thief of sight’ so, that early detection of glaucoma is very essential. In existing approach three methods are used to detect glaucoma namely Assessment of raised intraocular pressure (IOP).Assessment of abnormal visual field. Assessment of damaged ...

متن کامل

A Method of Segmentation For Glaucoma Screening Using Superpixel Classification

ABSTRACT: Glaucoma is a chronic eye disease that leads to vision loss. Detecting glaucoma in time is critical. The symptoms of the glaucoma disease occur when it is in advanced stage. Hence, glaucoma is called the silent thief of sight. Detecting the disease in time is very important. In this project, an optic disc and optic cup segmentation is used to identify the glaucoma disease in time. In ...

متن کامل

Reproducibility of topographic measures of the glaucomatous optic nerve head.

AIMS/BACKGROUND Laser scanning tomography provides an assessment of three dimensional optic disc topography. For the clinical purpose of follow up of glaucoma patients, the repeatability of the various measured variables is essential. In the present study, the reproducibility of morphometric variables calculated by the topographic scanning system, TopSS (Laser Diagnostic Technology, San Diego, ...

متن کامل

Morphometric Optic Nerve Head Analysis in Glaucoma Patients: A Comparison between the Simultaneous Nonmydriatic Stereoscopic Fundus Camera (Kowa Nonmyd WX3D) and the Heidelberg Scanning Laser Ophthalmoscope (HRT III)

Purpose. To investigate the agreement between morphometric optic nerve head parameters assessed with the confocal laser ophthalmoscope HRT III and the stereoscopic fundus camera Kowa nonmyd WX3D retrospectively. Methods. Morphometric optic nerve head parameters of 40 eyes of 40 patients with primary open angle glaucoma were analyzed regarding their vertical cup-to-disc-ratio (CDR). Vertical CDR...

متن کامل

Morphometric parameters of the optic disc in normal and glaucomatous eyes based on time-domain optical coherence tomography image analysis.

BACKGROUND AND OBJECTIVE Assessment of optic disc morphology is essential in diagnosis and management of visual impairment. The aim of this study was to evaluate associations between optic disc morphometric parameters, i.e., size and shape, and age, gender, and ocular axial length in normal and glaucomatous eyes based on time-domain optical coherence tomography image analysis. MATERIALS AND M...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Experimental eye research

دوره 91 3  شماره 

صفحات  -

تاریخ انتشار 2010