Recent Experimental Results from the NA62 Gigatracker Prototypes: an Hybrid Silicon Pixel Detector with 100 ps Time Resolution
نویسنده
چکیده
G. Aglieri Rinellaa,V. Carassitic,A. Ceccuccia,E. Cortinad ,J. Daguina,G. Dellacasab,M. Fiorinia,P. Jarrona,J. Kaplona,A. Klugea,F. Marchettoa,E. Martind ,A. Mapellia, f ,G. Mazzab,M. Morela,M. Noya,G. Nüssled ,P. Petagnaa,L. Perktolda,F. Petruccic,e,A. Cotta Ramusinoc,P. Riedlera,A. Rivettib,R. Wheadonb aCERN, Geneva Switzerland,bINFN Torino, Italy,cINFN Ferrare, Italy,dUCL Louvain la Neuve, Belgium, eUniversity of Ferrara, f EPFL Lausanne, Switzerland
منابع مشابه
Readout Electronics of the Na62 Gigatracker System
A crucial detector of the NA62 experiment is the beam spectrometer named Gigatracker. It consists of three stations of hybrid silicon pixels sensors with 150 ps (rms) of time resolution and 100 μm (rms) of space resolution. In addition the system operates under a high radiation environment and a high density of particles (up to 1.5 MHz/mm in the centre and 0.8 1 GHz in total). To meet these req...
متن کاملAn ultra fast silicon pixel detector for the NA 62 experiment : the Gigatracker
The beam spectrometer of the NA62 experiment has to sustain high and non-uniform beam rate (∼1.5 MHz/mm 2 in the hot center and 0.8-1.0 GHz in total, hence the name Gigatracker) and should preserve beam divergence and limit beam hadronic interactions. The Gigatracker has to provide precise momentum, time and angular measurements on every single track of the secondary 75 GeV/c hadron beam with a...
متن کاملMicrofluidic cooling for detectors and electronics
Micro-channel cooling is gaining considerable attention as an alternative technique for cooling of high energy physics detectors and front-end electronics. This technology is being evaluated for future tracking devices, where material budget limitations are a major concern. It is currently under investigation as an option for the cooling of the NA62 Gigatracker silicon pixel detector, where a m...
متن کاملKaon identification in the NA62 experiment at CERN
The main purpose of the NA62 experiment at the CERN SPS is to measure the Branching Ratio of the ultra-rare kaon decay K+ → π+νν̄ with 10% accuracy. This will be achieved by collecting about 100 events with a Signal to Background ratio of 10/1. NA62 will use a 75 GeV/c unseparated charged hadron beam and a kaon decay-in-flight technique. For the kaon identification a hydrogen gas-filled differen...
متن کامل5 v 1 2 1 N ov 2 00 0 Beam Test of BTeV Pixel Detectors
The silicon pixel vertex detector is one of the key elements of the BTeV spectrometer. Detector prototypes were tested in a beam at Fermilab. We report here on the measured spatial resolution as a function of the incident angles for different sensorreadout electronics combinations. We compare the results with predictions from our Monte Carlo simulation.
متن کامل