Conceptual design of the superconducting magnet for the 250 MeV proton cyclotron

نویسندگان

  • Yong Ren
  • Xiaogang Liu
  • Xiang Gao
چکیده

BACKGROUND The superconducting cyclotron is of great importance to treat cancer parts of the body. To reduce the operation costs, a superconducting magnet system for the 250 MeV proton cyclotron was designed to confirm the feasibility of the superconducting cyclotron. FINDINGS The superconducting magnet system consists of a pair of split coils, the cryostat and a pair of binary high temperature superconductor current leads. The superconducting magnet can reach a central magnetic field of about 1.155 T at 160 A. The three GM cryocooler with cooling capacities of 1.5 W at 4.5 K and 35 W at 50 K and one GM cryocooler of 100 W at 50 K were adopted to cool the superconducting magnet system through the thermosiphon technology. CONCLUSION The four GM cryocoolers were used to cool the superconducting magnet to realize zero evaporation of the liquid helium.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Status Report of the Accel 250 Mev Medical Cyclotron

Since 2001 a superconducting cyclotron for proton therapy has been designed in collaboration with the National Superconducting Cyclotron Laboratory (NSCL) at ACCEL Instruments GmbH [1]. The design is based on a NSCL proposal originating from 1993 [2]. In the recent years two cyclotrons of this type were built, tested as far as magnetic and cryogenic properties are concerned and installed at the...

متن کامل

Design of the Energy Selection System for Proton Thera- Py Based on Geant4*

Huazhong University of Science and Technology (HUST) has planned to build a proton therapy facility based on an isochronous superconducting cyclotron. The 250 MeV/500 nA proton beam is extracted from a superconducting cyclotron. To modulate beam energy, an energy selection system is essential in the beamline. The simulation based on Geant4 has been performed for the energy selection system and ...

متن کامل

COMPACT SUPERCONDUCTING 250 MeV PROTON CYCLOTRON FOR THE PSI PROSCAN PROTON THERAPY PROJECT

A cyclotron for proton therapy has to fulfil many requirements set by the specific operational and safety needs of a medical facility and the medical environment. These are for instance high extraction efficiency, high availability and reliability, simple and robust operation. ACCEL Instruments GmbH has refined the design concept of a medical cyclotron for the PSI PROSCAN project with the objec...

متن کامل

A Cw Ffag for Proton Computed Tomography

An advantage of the cyclotron in proton therapy is the continuous (CW) beam output which reduces complexity and response time in the dosimetry requirements and beam controls. A CW accelerator requires isochronous particle orbits at all energies through the acceleration cycle and present compact isochronous cyclotrons for proton therapy reach only 250 MeV (kinetic energy) which is required for p...