Invalidity of hand heating as a method to arterialize venous blood.
نویسندگان
چکیده
We have assessed in normal subjects the validity of using hand heating to obtain "arterialized" venous blood by biochemical comparison of results for "arterialized" venous and true arterial (radial artery) blood samples. The heating regimen involved placing one hand in an air-heated box at 45-50 degrees C for 45 min. This method produced blood that was "arterialized" for lactate, PCO2, HbO2, and Hb but not for ammonia or PO2; it had no effect on determinations of pyruvate or glucose in plasma. Despite using a lower air temperature than previous workers, we observed thermal injury in one volunteer. Further, there was considerable between-subject variation in the effect of hand heating on blood gases. This suggests that blood gases should be measured in the "arterialized" samples at regular intervals from the start of hand heating in each patient to determine whether maximal "arterialization" has been achieved, to avoid making misleading biochemical measurements. Given the wide range in degree of observed "arterialization," we question the validity of this method.
منابع مشابه
Critical evaluation of the 'heated-hand-technique' for obtaining 'arterialized' venous blood: incomplete arterialization and alterations in glucagon responses.
In order to test the degree of 'arterialization' and the occurrence of arterio- (or capillary-) venous differences in glucose concentrations for commonly used blood sampling sites (including the retrogradely cannulated dorsal hand vein with application of dry heat to this hand/arm--the 'heated-hand-technique'), oxygen partial pressure (oxygen saturation) and plasma glucose was determined in blo...
متن کاملبررسی همخوانی نوارهای سنجش قند خون بتاچک با روش استاندارد
Diabetes mellitus (DM) is the commonest cause of renal failure, blindness and non traumatic amputation. According to ADA, prevention of DM complications is possible through monitoring and control of blood glucose levels.Methods: The Betachek strip, produced in Australia, is able to determine biood glucose level with no need for electronic glucometer devices.Results: In this study, we compared v...
متن کاملSurvey of a Practical Approach to Central Venous Catheterization in Pediatric Patients
Background Central venous catheter (CVC) is used for measuring hemodynamic variables, transfusion of blood, fluids and medications when peripheral vascular lack sufficiency. Unfortunately CVC is associated with many complications ranging from anxiety and discomfort for the patient to severe mechanical side effects such as arterial lacerations, pleural and pericardial injury as well as infection...
متن کاملA Comparative Study of Blood Glucose Measurements Using Glucometer Readings and the Standard Method in the Diagnosis of Neonatal Hypoglycemia
Background: Hypoglycemia is one of the most common neonatal disorders, associated with severe complications. There has been a great deal of controversy regarding the definition and screening of hypoglycemia. Therefore, in this study, we aimed to determine a cut-off value for blood glucose level in glucometer readings. Methods: This cross-sectional study was conducted on 238 newborns at risk of ...
متن کاملThe comparison of normal venous blood with
Introduction: Cupping therapy (hejamat) is one of the therapeutic methods used in traditional medicine that it is still common in many of the contemporary societies. In spite of the progress of science, we have less information on the traditional and alternative medicine including cupping. With the study of mechanism of action of cupping, it will be more convincing for the traditional medic...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Clinical chemistry
دوره 36 5 شماره
صفحات -
تاریخ انتشار 1990