Bedside cardiac monitoring.

نویسنده

  • C Jacobson
چکیده

Most newer bedside monitors allow monitoring of 2 leads simultaneously but only allow monitoring of one precordial (V) lead at a time. Leads V1 or V6 can be obtained by using a 5-lead bedside monitoring cable with limb electrodes placed as shown in Figure 1: • Arm electrodes should be placed on the shoulders as close as possible to where the arms join the torso. Although the arm electrodes tiate wide QRS rhythms. Research consistently shows that leads V1 and V6 (or their bipolar equivalents MCL1 and MCL6) are the best leads for differentiating wide QRS rhythms. The QRS morphologies displayed in these leads are invaluable in differentiating ventricular tachycardia from supraventricular tachycardia with aberrant conduction. Other criteria used in the differential diagnosis, such as the presence of AV dissociation, QRS ProtocolsforPractice

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Skilled cardiac monitoring at the bedside: an algorithm for success.

he American Association of Critical-Care Nurses (AACN) posted 2 practice alerts to address issues in cardiac monitoring in 2004 and updated them in April 2008. The alerts addressed 2 main reasons for use of cardiac bedside monitoring. The first reason is to detect and provide early intervention for episodes of myocardial ischemia and injury. Skilled Cardiac Monitoring at the Bedside: An Algorit...

متن کامل

Does it require to exclude cardiobiliary reflex in every acute coronary syndrome follow up patient with bedside ultrasound on emergency department

 In emergency department, physicians can diagnose pulseless electrical activity, asystole, pericardial effusions, ischemic heart disease, wall motion abnormalities, valvular cardiac disease volume status or global cardiac function evaluating with electrocardiographic findings or using bedside c...

متن کامل

Protocol Adherence in Prehospital Medical Care Provided for Patients with Chest Pain and Loss of Consciousness; a Brief Report

INTRODUCTION Although many protocols are available in the field of the prehospital medical care (PMC), there is still a notable gap between protocol based directions and applied clinical practice. This study measures the rate of protocol adherence in PMC provided for patients with chest pain and loss of consciousness (LOC). METHOD In this cross-sectional study, 10 educated research assistants...

متن کامل

ANMCO/AIIC/SIT Consensus Information Document: definition, precision, and suitability of electrocardiographic signals of electrocardiographs, ergometry, Holter electrocardiogram, telemetry, and bedside monitoring systems

The electrocardiogram (ECG) signal can be derived from different sources. These include systems for surface ECG, Holter monitoring, ergometric stress tests, and telemetry systems and bedside monitoring of vital parameters, which are useful for rhythm and ST-segment analysis and ECG screening of electrical sudden cardiac death predictors. A precise ECG diagnosis is based upon correct recording, ...

متن کامل

Bench-to-bedside review: An approach to hemodynamic monitoring - Guyton at the bedside

Hemodynamic monitoring is used to identify deviations from hemodynamic goals and to assess responses to therapy. To accomplish these goals one must understand how the circulation is regulated. In this review I begin with an historical review of the work of Arthur Guyton and his conceptual understanding of the circulation and then present an approach by which Guyton's concepts can be applied at ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Critical care nurse

دوره 18 3  شماره 

صفحات  -

تاریخ انتشار 1998