Reference chart derived from post-stent-implantation intravascular ultrasound predictors of 6-month expected restenosis on quantitative coronary angiography.

نویسندگان

  • P J de Feyter
  • P Kay
  • C Disco
  • P W Serruys
چکیده

BACKGROUND Intravascular ultrasound (IVUS)-guided stent implantation and the availability of a reference chart to predict the expected in-stent restenosis rate based on operator-dependent IVUS parameters may interactively facilitate optimal stent placement. The use of IVUS guidance protects against undue risks of dissection or rupture. METHODS AND RESULTS IVUS-determined post-stent-implantation predictors of 6-month in-stent restenosis on quantitative coronary angiography (QCA) were identified by logistic regression analysis. These predictors were used to construct a reference chart that predicts the expected 6-month QCA restenosis rate. IVUS and QCA data were obtained from 3 registries (MUSIC [Multicenter Ultrasound Stenting in Coronaries study], WEST-II [West European Stent Trial II], and ESSEX [European Scimed Stent EXperience]) and 2 randomized in-stent restenosis trials (ERASER [Evaluation of ReoPro And Stenting to Eliminate Restenosis] and TRAPIST [TRApidil vs placebo to Prevent In-STent intimal hyperplasia]). In-stent restenosis was defined as luminal diameter stenosis >50% by QCA. IVUS predictors were minimum and mean in-stent area, stent length, and in-stent diameter. Multiple models were constructed with multivariate logistic regression analysis. The model containing minimum in-stent area and stent length best fit the Hosmer-Lemeshow goodness-of-fit test. This model was used to construct a reference chart to calculate the expected 6-month restenosis rate. CONCLUSIONS The expected 6-month in-stent restenosis rate after stent implantation for short lesions in relatively large vessels can be predicted by use of in-stent minimal area (which is inversely related to restenosis) and stent length (which is directly related to restenosis), both of which can be read from a simple reference chart.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Intravascular ultrasound predictors of angiographic restenosis after sirolimus-eluting stent implantation.

AIMS In many countries, drug-eluting stent implantation is the dominant interventional strategy. We evaluated the clinical, angiographic, procedural, and intravascular ultrasound (IVUS) predictors of angiographic restenosis after sirolimus-eluting stent (SES) implantation. METHODS AND RESULTS SES implantation was successfully performed in 550 patients with 670 native coronary lesions. Six-mon...

متن کامل

Arterial remodeling patterns before intervention predict diffuse in-stent restenosis: an intravascular ultrasound study.

OBJECTIVES The aim of this retrospective study was to determine the predictors of diffuse in-stent restenosis (ISR) among the lesions causing the first ISR by intravascular ultrasound (IVUS) studies. BACKGROUND Although some predictors of diffuse ISR have been reported, parameters on IVUS relating to diffuse ISR are not well characterized. METHODS We classified 52 ISR lesions that had under...

متن کامل

Lack of neointimal proliferation after implantation of sirolimus-coated stents in human coronary arteries: a quantitative coronary angiography and three-dimensional intravascular ultrasound study.

BACKGROUND Restenosis remains an important limitation of interventional cardiology. Therefore, we aimed to determine the safety and efficacy of sirolimus (a cell-cycle inhibitor)-coated BX Velocity stents. METHODS AND RESULTS Thirty patients with angina pectoris were electively treated with 2 different formulations of sirolimus-coated stents (slow release [SR], n=15, and fast release [FR], n=...

متن کامل

Cytomegalovirus, Chlamydia pneumoniae, and Helicobacter pylori IgG antibodies and restenosis after stent implantation: an angiographic and intravascular ultrasound study.

OBJECTIVE To determine the impact of previous infection with cytomegalovirus, Chlamydia pneumoniae, and Helicobacter pylori on neointimal proliferation after coronary angioplasty with stent implantation. DESIGN The study population was made up of 180 patients who had stent implantation in a native coronary artery with systematic angiographic and intravascular ultrasound (IVUS) follow up at si...

متن کامل

Intravascular ultrasound guidance improves angiographic and clinical outcome of stent implantation for long coronary artery stenoses: final results of a randomized comparison with angiographic guidance (TULIP Study).

BACKGROUND Long coronary lesions treated with stents have a poor outcome. This study compared the 6-month outcome of stent implantation for long lesions in patients randomized to intravascular ultrasound (IVUS; n=73) or angiographic guidance (n=71). METHODS AND RESULTS Stenoses >20 mm in length and a reference diameter that permitted a stent diameter > or =3 mm were eligible. Primary end poin...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Circulation

دوره 100 17  شماره 

صفحات  -

تاریخ انتشار 1999