Severe cutaneous aspergillosis in a premature neonate linked to nonsterile disposable glove contamination?

نویسندگان

  • Claire Stock
  • Magali Veyrier
  • Hélène Raberin
  • Pascal Fascia
  • Isabelle Rayet
  • Marie Pierre Lavocat
  • Georges Teyssier
  • Philippe Berthelot
چکیده

After having eliminated a dysfunction of the hospital's ventilation system and any other possible environmental reservoir, the investigation of a fatal case of primary cutaneous aspergillosis in a neonate with extremely low birth weight led to the conclusion that nonsterile disposable gloves kept stored in their native packages were the likely source of contamination.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Bacterial contamination of nonsterile disposable gloves before use.

BACKGROUND After Bacillus cereus recovery in opened boxes of disposable gloves, the bacteriological contamination of disposable nonsterile gloves kept stored in native packages was investigated prospectively. METHODS Thirty-six commercially available nonsterile nonpowdered disposable gloves made of latex, vinyl, or nitrile were cultured. RESULTS A large variety of spore-forming and non-spor...

متن کامل

Contaminação Microbiana Das Luvas De Procedimento Após a Abertura Da Caixa E Durante Sua Exposição Ambiental Contaminación Microbiana De Guantes De Procedimiento Luego De La Abertura De La Caja Y Durante Exposición Ambiental

The objective of this study was to quantify the colony forming units (cfu) on latex procedure gloves in the beginning, middle, and end of the containers in real (professional) and controlled (researcher) gloving situations; evaluate the microbial load of the gloves, considering the time of exposure in the environment. This comparative prospective study was conducted at an intensive care unit of...

متن کامل

Permeation of Herbicidal Dichlobenil From a Casoron Formulation Through Nitrile Gloves

The aim of this study was to measure permeation of the herbicide dichlobenil in Casoron 4G through disposable and chemically protective nitrile gloves using an American Society for Testing and Materials-type permeation cell and a closed-loop system employing two different solvents (hexane and water) and two different challenge situations (aqueous emulsion and solid formulation). Capillary gas c...

متن کامل

Invasive Aspergillosis in Pediatric Hematology Oncology Ward

Background: Patients with prolonged neutropenia and/or severe underlying immunosuppression are at thegreatest risk for disseminated aspergillosis. This study was undertaken to determine the incidence of invasiveaspergillosis by Platelia Aspergillus enzyme-linked immunosorbent assay ELISA kit in high risk children admitted tothe hematology ward of Dr. Faghihi hospital, Shiraz University of Medic...

متن کامل

Severe Apnea in a Premature Infant after Accidental Vancomycin Overdose Responsive to Treatment with Exchange Transfusion

Background: Mostly seen toxicities following vancomycin are ototoxicity and nephrotoxicity. We here report a very low birth weight preterm neonate who developed severe episodes of apnea after accidental iatrogenic vancomycin overdose, responsive to treatment with double volume exchange transfusion. Case report: A preterm neonate weighing 1380 grams received two doses of 10-fold of the normal do...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • American journal of infection control

دوره 40 5  شماره 

صفحات  -

تاریخ انتشار 2012