Design and comparison of two eight-channel transmit/receive radiofrequency arrays for in vivo rodent imaging on a 7 T human whole-body MRI system.

نویسندگان

  • Stephan Orzada
  • Stefan Maderwald
  • Sophia L Göricke
  • Nina Parohl
  • Susanne C Ladd
  • Mark E Ladd
  • Harald H Quick
چکیده

PURPOSE Magnetic resonance imaging (MRI) of rodents can be expected to be a growing application, particularly when translatory imaging research "from mouse to man" is envisioned. 7 T high-field human whole-body MR systems provide a powerful platform for high-resolution small animal imaging. For achieving adequate spatial resolution, dedicated radiofrequency coils have to be designed to provide the necessary signal-to-noise ratio (SNR). METHODS Two different multichannel transmit/receive radiofrequency (RF) arrays for high-resolution imaging of rodents on a human whole-body 7 T MR system have been developed and evaluated in comparative in vitro phantom experiments and in vivo experiments in rats. The first coil was a one-channel birdcage RF transmit/eight-channel loop RF receive phased-array coil; the second coil was an eight-channel RF transmit/receive stripline phased-array coil with inverted microstrip lines--A coil design that here is described for the first time for dedicated small animal MR imaging. RESULTS Both coil setups provided the high SNR necessary for high-resolution MRI in rodents. The eight-channel loop RF array, with its larger inner diameter and transparent layout, provided better overall signal homogeneity and enabled easy visual monitoring; the eight-channel stripline RF array provided overall higher SNR and better parallel imaging acceleration performance. CONCLUSIONS The results show that both coil designs are suitable for small animal imaging on 7 T whole-body systems; the preferred coil depends on the demands of the application.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Assessment of the Characteristics of MRI Coils in Terms of RF Non-Homogeneity Using Routine Spin Echo Sequences

Introduction: One of the major causes of image non-uniformity in MRI is due to the existence of  non-homogeneity in RF receive and transmit. This can be the most effective source of error in  quantitative  studies  in  MRI  imaging.  Part  of  this  non-homogeneity  demonstrates  the  characteristics of RF coil and part of it is due to the interaction of RF field with the material being  imaged...

متن کامل

7T Human in vivo Cardiac Imaging with an 8-Channel Transmit/Receive Array

Introduction: There are numerous reasons why cardiac MRI at high field strengths is a potentially challenging endeavor: the heart is subject to cardiac and breathing motion, necessitating peripheral pulse or preferably ECG-triggered sequences with breath holds or navigator sequences to capture the beating heart. Moreover, MRI signal generation is difficult due to inhomogeneous RF signal transmi...

متن کامل

Metamaterial-based transmit and receive system for whole-body magnetic resonance imaging at ultra-high magnetic fields

Magnetic resonance imaging (MRI) at ultra-high fields (UHF), such as 7 T, provides an enhanced signal-to-noise ratio and has led to unprecedented high-resolution anatomic images and brain activation maps. Although a variety of radio frequency (RF) coil architectures have been developed for imaging at UHF conditions, they usually are specialized for small volumes of interests (VoI). So far, whol...

متن کامل

A High-Throughput Eight-Channel Probe Head for Murine MRI at 9.4 T

Murine MRI studies are conducted on dedicated MR systems, typically equipped with ultra-high-field magnets (>or=4.7 T; bore size: approximately 12-25 cm), using a single transmit-receive coil (volume or surface coil in linear or quadrature mode) or a transmit-receive coil combination. Here, we report on the design and characterization of an eight-channel volume receive-coil array for murine MRI...

متن کامل

An eight-channel phased array RF coil for spine MR imaging at 7 T.

OBJECTIVE To develop a transmit/receive radiofrequency (RF) array for MR imaging of the human spine at 7 T. The prototype is characterized in simulations and bench measurements, and the feasibility of high-resolution spinal cord imaging at 7 T is demonstrated in in vivo images of volunteers. MATERIALS AND METHODS The RF phased array consists of 8 overlapping surface loop coils with a dimensio...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Medical physics

دوره 37 5  شماره 

صفحات  -

تاریخ انتشار 2010