Pericarditis-Induced Hyponatremia after Cardiac Electronic Implantable Device (CEID) Procedures

نویسندگان

  • Elnaz Rakhshan
  • Seyed Abbas Mirabbasi
  • Bahar Khalighi
  • Koroush Khalighi
چکیده

BACKGROUND Pericardial effusion along with pleural effusion is one of the rare complications of permanent pacemaker placement. Although extremely uncommon, it is more prevalent in elderly patients and may be complicated with hyponatremia. CASE REPORT We observed development of hyponatremia in association with pericardial effusion and pleural effusion, within one month after pacemaker placement in two women with BMI of <20. Case 1: An 87-year-old woman underwent implantation of a transvenous AV sequential pacemaker because of severe bradycardia and complete heart block. Three weeks later, she complained of progressive left-sided rib cage pain and poor oral intake. Her echocardiography showed a moderately large amount of pericardial effusion, but no evidence of tamponade. She also had hyponatremia (Na=119 mEq/dl). Extensive work-up suggested hyponatremia presumably due to SIADH, caused by pericardial/pleural effusion. Case 2: An 83-year-old woman with history of severe sick sinus syndrome required a transvenous Av sequential pacemaker 3 weeks before. She then presented with generalized weakness, fatigue, and poor oral intake of over one week. There was a small-moderate pericardial effusion echocardiographically, and her serum sodium was 116 mEq/dl. CONCLUSIONS Although extremely uncommon, pericarditis can develop following transvenous pacemaker insertion, which may result in hyponatremia, likely due to SIADH. The most common scenario is an elderly, petite woman with low BMI (<20), usually after using a helical screw/active fixation pacing leads, several weeks post-implant. Early recognition and therapy can significantly improve outcome and morbidity.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Infectious endocardial intracardiac defibrillator lead, infectious pericarditis, and delayed constrictive pericarditis

The usage of Implantable Cardiac Defibrillator (ICD) since 1980s is becoming more popular these days. The rate of both, endocarditis and constrictive pericarditis are low but it still needs attention. We are reporting a rare case of ICD endocarditis as a result of toe infection in a diabetic patient. This was followed by infectious pericarditis after device removal by open heart surgery and the...

متن کامل

Node-First Kawasaki Disease Presented with Marked Pancarditis: a Case Report

Kawasaki disease is an acute inflammatory disorder of medium-sized arteries that predominantly affects cardiac coronary arteries and children under the age of 5 years. Cardiac involvement usually happens later than 10 days after the onset of illness. Most of cardiac complications are coronary artery abnormalities (ectasia or aneurysms) and subclinical myocarditis. Clinical myocarditis (symptoma...

متن کامل

Incidence and Costs Related to Lead Damage Occurring Within the First Year After a Cardiac Implantable Electronic Device Replacement Procedure.

BACKGROUND Inadvertent damage to leads for transvenous pacemakers, implantable cardioverter-defibrillators, and cardiac resynchronization therapy defibrillators is an important complication associated with generator-replacement procedures. We sought to estimate the incidence and costs associated with transvenous lead damage following cardiac implantable electronic device replacement. METHODS ...

متن کامل

Implantable cardioverter-defibrillator in a patient with dextrocardia situs inversus

Background: Dextrocardia is a congenital anomaly, which may have coexistent coronary artery disease (CAD), arrhythmias and conventional indications for device therapy. However, the implantation of transvenous leads can be technically challenging and the approach needs to be tailored to the patient's individual anatomy. Case presentation: A 54-year-old male with dextrocardia situs inversus and i...

متن کامل

Combined Subpectoral Implantation of Implantable Cardioverter-Defibrillator and Augmentation Mammoplasty in a Young Female Patient

Subcutaneous implantation of a cardiac implantable electronic device is the standard method. Occasionally, subpectoral cardiac implantable electronic device (CIED) implantation via axillary incisions is performed in young female patients for cosmetic purposes. Because subpectoral CIED implantation and augmentation mammoplasty involve the same layer, it is feasible to perform both procedures sim...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 16  شماره 

صفحات  -

تاریخ انتشار 2015