Active aspiration of suprachoroidal hemorrhage using a guarded needle.
نویسندگان
چکیده
BACKGROUND AND OBJECTIVE To describe a novel technique using a guarded needle to drain suprachoroidal hemorrhage. PATIENTS AND METHODS A guarded needle is used to drain suprachoroidal hemorrhage under direct microscope visualization. A scleral buckling sleeve is used to create a guarded 26-gauge needle to avoid over-penetration of the needle beyond the suprachoroidal space. Active extrusion can be used to drain suprachoroidal blood. RESULTS The authors report two cases in which active aspiration using a guarded needle was successful in draining suprachoroidal hemorrhage without complications. In both cases, the vitreous cavity could be restored, allowing for subsequent pars plana vitrectomy. CONCLUSION The technique of active aspiration using a guarded needle optimizes surgeon control of suprachoroidal hemorrhage drainage and also has the added benefit of easy transition to secondary vitrectomy after drainage has been completed.
منابع مشابه
Combination of aspiration and non-aspiration fine needle biopsy for cytological diagnosis of thyroid nodules
Background: Good cytological sample is very important for the cytological diagnosis of thyroid nodules. The aim of this study was to evaluate the adequacy of prepared samples by the combination of aspiration and non- aspiration fine needle biopsy. Methods: In this descriptive – analytical study, sampling was done simultaneously for each patient in fine needle aspiration and non-aspiration biops...
متن کاملSuprachoroidal gas injection as a complication of pars plana vitrectomy confirmed by computed tomography
BACKGROUND Suprachoroidal gas injection has been reported as a complication of pneumatic retinopexy, and the usefulness of B-scan ultrasonography has been reported. A case of suprachoroidal gas injection as a complication of pars plana vitrectomy confirmed by computed tomography (CT) is presented here. METHODS A 64-year-old woman developed a vitreous hemorrhage due to a retinal tear secondary...
متن کامل193 nm excimer laser sclerostomy in pseudophakic patients with advanced open angle glaucoma.
A modified open mask system incorporating an en face air jet to dry the target area during ablation and a conjunctival plication mechanism, which allows ab externo delivery of the 193 nm excimer laser without prior conjunctival dissection, has been developed to form small bore sclerostomies accurately and atraumatically. Full thickness sclerostomies, and sclerostomies guarded by a smaller inter...
متن کاملComparison of fine needle aspiration and direct skin smear in the diagnosis of acute cutaneous leishmaniasis: polymerase chain reaction as a reference method
Background: Accurate diagnosis of cutaneous leishmaniasis wouldavoid unnecessary treatment and scar formation. Direct smear isthe most common method for the diagnosis of this disease but itsnegative result could not rule out the infection; so, the need formore sensitive methods is obvious. We conducted this study tocompare the efficiency of direct skin smear with smears preparedby fine needle a...
متن کاملSteroid hormone receptors, MIB-1, p53, and c-erb-B2 expression on breast cancer: Comparison of immunohistochemistry on cell block and fine needle aspiration and tissue sample, in northwest Iran
Background: Fine-needle aspiration of breast cancer often provides moderate cellular material that is representative of the tumors. These samples can be used not only for cytological diagnosis but also to obtain information on the prognosis and likely response to therapy by using immunohistochemical staining studies. Methods: We assessed the degree of correlation between prognostic biologic ma...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Ophthalmic surgery, lasers & imaging retina
دوره 45 2 شماره
صفحات -
تاریخ انتشار 2014