Validation of extravascular lung water measurement by single transpulmonary thermodilution: human autopsy study

نویسندگان

  • Takashi Tagami
  • Shigeki Kushimoto
  • Yasuhiro Yamamoto
  • Takahiro Atsumi
  • Ryoichi Tosa
  • Kiyoshi Matsuda
  • Renpei Oyama
  • Takanori Kawaguchi
  • Tomohiko Masuno
  • Hisao Hirama
  • Hiroyuki Yokota
چکیده

INTRODUCTION Gravimetric validation of single-indicator extravascular lung water (EVLW) and normal EVLW values has not been well studied in humans thus far. The aims of this study were (1) to validate the accuracy of EVLW measurement by single transpulmonary thermodilution with postmortem lung weight measurement in humans and (2) to define the statistically normal EVLW values. METHODS We evaluated the correlation between pre-mortem EVLW value by single transpulmonary thermodilution and post-mortem lung weight from 30 consecutive autopsies completed within 48 hours following the final thermodilution measurement. A linear regression equation for the correlation was calculated. In order to clarify the normal lung weight value by statistical analysis, we conducted a literature search and obtained the normal reference ranges for post-mortem lung weight. These values were substituted into the equation for the correlation between EVLW and lung weight to estimate the normal EVLW values. RESULTS EVLW determined using transpulmonary single thermodilution correlated closely with post-mortem lung weight (r = 0.904, P < 0.001). A linear regression equation was calculated: EVLW (mL) = 0.56 × lung weight (g) - 58.0. The normal EVLW values indexed by predicted body weight were approximately 7.4 ± 3.3 mL/kg (7.5 ± 3.3 mL/kg for males and 7.3 ± 3.3 mL/kg for females). CONCLUSIONS A definite correlation exists between EVLW measured by the single-indicator transpulmonary thermodilution technique and post-mortem lung weight in humans. The normal EVLW value is approximately 7.4 ± 3.3 mL/kg. TRIAL REGISTRATION UMIN000002780.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Extravascular lung water assessed by transpulmonary single thermodilution and postmortem gravimetry in sheep

INTRODUCTION Acute lung injury is associated with accumulation of extravascular lung water (EVLW). The aim of the present study was to compare two methods for quantification of EVLW: transpulmonary single thermodilution (EVLWST) and postmortem gravimetric (EVLWG). METHODS Eighteen instrumented and awake sheep were randomly assigned to one of three groups. All groups received Ringer's lactate ...

متن کامل

Accuracy and limits of transpulmonary dilution methods in estimating extravascular lung water after pneumonectomy.

STUDY OBJECTIVES The measurement of extravascular lung water index by double indicator (EVLWIdi) or the measurement of extravascular lung water index by transpulmonary thermodilution (EVLWItt) could be useful after pneumonectomy. Since pulmonary blood flow and volume are altered after pneumonectomy, the validity of these methods is uncertain. This study has compared measurements of EVLWIdi and ...

متن کامل

Extravascular lung water and the pulmonary vascular permeability index may improve the definition of ARDS

The recent Berlin definition has made some improvements in the older definition of acute respiratory distress syndrome (ARDS), although the concepts and components of the definition remained largely unchanged. In an effort to improve both predictive and face validity, the Berlin panel has examined a number of additional measures that may reflect increased pulmonary vascular permeability, includ...

متن کامل

Measurement of extravascular lung water in patients with pulmonary edema.

MEASUREMENT OF EXTRAVASCULAR lung water has been a topic of major interest for more than two decades (1, 5, 19). In the recent article by Effros et al. (2), they provide a review of current and past efforts to measure extravascular lung water with thermal and osmotic dilution methods. The authors discuss several of the limitations of these methods, including problems related to early recirculat...

متن کامل

Simplified lung ultrasound protocol shows excellent prediction of extravascular lung water in ventilated intensive care patients

INTRODUCTION Ultrasound of the lung and quantification of B lines was recently introduced as a novel tool to detect overhydration. In the present study, we aimed to evaluate a four-region protocol of lung ultrasound to determine the pulmonary fluid status in ventilated patients in the intensive care unit. METHODS Fifty patients underwent both lung ultrasound and transpulmonary thermodilution ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 14  شماره 

صفحات  -

تاریخ انتشار 2010