Relationship among Corneal Biomechanics, Anterior Segment Parameters, and Geometric Corneal Parameters
نویسندگان
چکیده
Purpose. To investigate the relationship between corneal biomechanical parameters, anterior segment parameters, and geometric corneal parameters in a healthy Caucasian group. Methods. This retrospective study included the healthy eyes with best corrected visual acuity of at least 20/40 of 122 Caucasian subjects. The anterior segment parameters and geometric corneal parameters such as corneal volume, central corneal thickness, horizontal and vertical corneal radii, anterior and posterior steep, and flat keratometric values were measured with a Scheimpflug camera. The biomechanical properties were measured with Ocular Response Analyzer. Results. One hundred and twenty-two healthy Caucasian subjects (67 males, 55 females) with a mean age of 45.32 ± 20.23 were enrolled. Both corneal hysteresis and corneal resistance factor were positively correlated with CCT (r = 0.529, p < 0.001; r = 0.638, p < 0.001) and CV (r = 0.635, p < 0.001; r = 0.579, p < 0.001) and negatively correlated with age (r = -0.373, p < 0.001; r = -0.249, p < 0.001). Both in age-gender and multivariate models, CH and CRF had statistically significant negative association with the posterior steep K value. Conclusions. CH and CRF are negatively correlated with posterior steep and average posterior K values.
منابع مشابه
The relationship between corneal biomechanics and anterior segment parameters in the early stage of orthokeratology
To investigate the relationship between corneal biomechanics and anterior segment parameters in the early stage of overnight orthokeratology.Twenty-three eyes from 23 subjects were involved in the study. Corneal biomechanics, including corneal hysteresis (CH) and corneal resistance factor (CRF), and parameters of the anterior segment, including corneal curvature, central corneal thickness (CCT)...
متن کاملThe biomechanical properties of the cornea and anterior segment parameters
BACKGROUND To investigate the biomechanical properties of the cornea measured with the Ocular Response Analyzer (ORA) and their association with the anterior segment parameters representing the geometric dimensions including the corneal volume and anterior chamber volume. METHODS A retrospective review of 1020 patients who visited the BGN Eye Clinic was done. The mean radius of the corneal cu...
متن کاملRepeatability of Ocular Measurements with a Dual-Scheimpflug Analyzer in Healthy Eyes
PURPOSE To assess the repeatability of the Galilei dual Scheimpflug analyzer (GDSA) in anterior segment examination. METHODS Fifty-two eyes from 52 healthy volunteers were prospectively and consecutively recruited. Anatomic, axial, refractive, and instantaneous parameters were measured with GDSA to provide a complete characterization of the anterior segment. Repeatability was assessed calcula...
متن کاملSingle session, intrauser repeatability of anterior chamber biometric and corneal pachy-volumetric parameters using a new Scheimpflug + Placido device
PURPOSE To analyze single session, intrauser reliability of a Scheimpflug device for anterior chamber (AC) and corneal parameters. METHODS In this observational study, 100 normal candidates underwent Scheimpflug analysis with Sirius 3D Rotating Scheimpflug Camera and Topography System (Costruzione Strumenti Oftalmici, Italy). Two scans in dark room conditions were performed by the same experi...
متن کاملTitle : the Variability of Corneal and Anterior Segment Parameters
30 Purpose: To analyse, describe and test diverse corneal and anterior segment parameters 31 in normal and keratoconic eyes to better understand the geometry of the keratoconic 32 cornea. 33 34 Method: 44 eyes from 44 keratoconic patients and 44 eyes from 44 healthy patients 35 were included in the study. The Pentacam System was used for the analysis of the 36 anterior segment parameters. New a...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
دوره 2016 شماره
صفحات -
تاریخ انتشار 2016