Standardization of 68Ge/68Ga Using Three Liquid Scintillation Counting Based Methods

نویسندگان

  • B. E. Zimmerman
  • J. T. Cessna
  • R. Fitzgerald
چکیده

A solution containing (68)Ge in equilibrium with its daughter, (68)Ga, has been standardized for the first time at the National Institute of Standards and Technology (NIST) using 3 liquid scintillation-based techniques: live-timed 4πβ -γ anticoincidence (LTAC) counting, the Triple-to-Double Coincidence Ratio (TDCR) method, and (3)H-standard efficiency tracing with the CIEMAT(1)/NIST (CNET) method. The LTAC technique is much less dependent on level scheme data and model-dependent parameters and was thus able to provide a reference activity concentration value for the master solution with a combined standard uncertainty of about 0.3 %. The other two methods gave activity concentration values with respective differences from the reference value of +1.2 % and -1.5 %, which were still within the experimental uncertainties. Measurements made on the NIST "4π"γ secondary standard ionization chamber allowed for the determination of calibration factors for that instrument, allowing future calibrations to be made for (68)Ge/(68)Ga without the need for a primary measurement. The ability to produce standardized solutions of (68)Ge presents opportunities for the development of a number of NIST-traceable calibration sources with very low (<1 %) relative standard uncertainties that can be used in diagnostic medical imaging.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Reduction of 68Ge activity containing liquid waste from 68Ga PET chemistry in nuclear medicine and radiopharmacy by solidification

PET with 68Ga from the TiO2- or SnO2- based 68Ge/68Ga generators is of increasing interest for PET imaging in nuclear medicine. In general, radionuclidic purity (68Ge vs. 68Ga activity) of the eluate of these generators varies between 0.01 and 0.001%. Liquid waste containing low amounts of 68Ge activity is produced by eluting the 68Ge/68Ga generators and residues from PET chemistry. Since clear...

متن کامل

Initial Clinical Experience with 68Ga-DOTA-NOC Prepared Using 68Ga from Nanoceria-polyacrylonitrile Composite Sorbent-based 68Ge/68Ga Generator and Freeze-dried DOTA-NOC Kits

Somatostatin receptor positron emission tomography-computed tomography (PET/CT) with 68Ga-1,4,7,10-tetraazacyclododecane-1,4,7,10-tetraacetic acid (DOTA) peptides have become an indispensable part of disease assessment in patients with neuroendocrine tumors and forms the basis of personalized therapy with peptide receptor-based radionuclide therapy. With growing utilization of PET/CT in develop...

متن کامل

Application of TDCR-Geant4 modeling to activity standardization

The LNE-LNHB, in charge of the French standards for radionuclide metrology, develops primary measurement methods intended for the calibration of secondary measuring instruments, such as used in hospitals, to determine the activity of radiopharmaceuticals injected into patients. The triple-to-double coincidence ratio (TDCR) method, based on liquid scintillation counting, is widely implemented fo...

متن کامل

Chemistry on Their Way into a New Century

68Ga faces a renaissance initiated by the development of new 68Ge/68Ga radionuclide generators, sophisticated 68Ga radiopharmaceuticals, preclinical research and state-of-the-art clincial diagnoses via positron emission tomography/computed tomography (PET/CT). A new type of 68Ge/68Ga generator became commercially available in the first years of the 21st century, with eluates based on hydrochlor...

متن کامل

Preclinical Studies of 68Ga-DOTATOC: Biodistribution Assessment in Syrian Rats and Evaluation of Absorbed Dose in Human Organs

Objective(s): Gallium-68 DOTA-DPhe1-Tyr3-Octreotide (68Ga-DOTATOC) has been applied by several European centers for the treatment of a variety of human malignancies. Nevertheless, definitive dosimetric data are yet unavailable. According to the Society of Nuclear Medicine and Molecular Imaging, researchers are investigating the safety and efficacy of this radiotracer to meet Food and Drug Admin...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 113  شماره 

صفحات  -

تاریخ انتشار 2008