Thermal changes and drill wear in bovine bone during implant site preparation. A comparative in vitro study: twisted stainless steel and ceramic drills.

نویسندگان

  • Natália Oliveira
  • Fernando Alaejos-Algarra
  • Javier Mareque-Bueno
  • Eduard Ferrés-Padró
  • Federico Hernández-Alfaro
چکیده

OBJECTIVES The purpose was to assess thermal changes and drill wear in bovine bone tissue with the use of twisted stainless steel and zirconia-based drills, during implant site preparation. METHODS A total of 100 implant site preparations were performed on bovine ribs using a surgical unit linked to a testing device, in order to standardize/simulate implant drilling procedures. Bone temperature variations and drilling force were recorded when drilling at a depth of 8 and 10 mm. A constant irrigation of 50 ml/min. (21±1°C) and drilling speed of 800 r.p.m. were used. Scanning electron microscopy analysis was preformed prior and after drilling. RESULTS Mean temperature increase with both drills at 8 mm was 0.9°C and at 10 mm was 2°C (P<0.0001). Statistical significant higher bone temperatures were obtained with stainless steel drill (1.6°C), when comparing with the ceramic drill (1.3°C) (P<0.05). Temperature increase was correlated with higher number of perforations (P<0.05) and drilling load applied. There was no significant association between drilling force applied and temperature increase by either drill or at either depth. No severe signs of wear of either drill were detected after 50 uses. CONCLUSIONS Drill material and design, number of uses, depth and drilling load applied appear to influence bone temperature variations during implant site preparation. Drilling depth was a predominant factor in bone temperature increase. Both drills can be used up to 50 times without producing harmful temperatures to bone tissue or severe signs of wear and deformation.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Biological Evaluation of Implant Drill Made from Zirconium Dioxide

PURPOSE Zirconia is a good candidate material in the dental field. In this study, we evaluated biological responses against a zirconia drill using a bone cavity healing model. MATERIALS AND METHODS Zirconia drills, stainless steel drills, and the drilled bone surface were observed by scanning electron microscopy (SEM), before and after cavity preparation. For the bone cavity healing model, th...

متن کامل

The influence of drill wear on cutting efficiency and heat production during osteotomy preparation for dental implants: a study of drill durability.

PURPOSE The authors evaluated, under conditions simulating implant placement, the cutting efficiency, durability, heat production, and wear of implant drills. MATERIALS AND METHODS Osteotomies were performed on bovine ribs using a surgical unit mounted in a testing apparatus. A software program controlled the apparatus and recorded temperatures, depths, and drilling times. Seven brands of dri...

متن کامل

Comparison of heat generation between internally guided (cannulated) single drill and traditional sequential drilling with and without a drill guide for dental implants.

PURPOSE To determine whether a wire-guided single drill protocol could be utilized without causing an increase in bone temperature beyond those seen with the traditional techniques of sequential drilling with and without a drill guide. MATERIALS AND METHODS A bovine femoral bone model was used with thermocouples and infrared temperature measurements to record thermal increase of the bone and ...

متن کامل

Effect of surgical drill guide and irrigans temperature on thermal bone changes during drilling implant sites - thermographic analysis on bovine ribs.

Background/Aim During drilling implant sites, mechanical energy is converted into thermal one resulting in transient rise in temperature of surrounding bone. The temperature of 47°C exeeding one minute impairs osseointegration, compromises mechanical properties of the local bone and could cause early implant failure. This in vitro study aimed to assess the effect of surgical drill guide and tem...

متن کامل

[Heat distribution within the bone tissue by rotary cutting instrument for IMZ implant. Heat analysis by a real-time thermography].

A highly skilled surgical technic is an important factor for the success of implant. But the heat generation during bone preparation will greatly affect the healing process of bone and prognosis of implant. In this study, the heat occurrence and distribution during bone preparation which performed on an in vitro mandible model (ribs of pig) were considered with the aid of a real-time thermograp...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical oral implants research

دوره 23 8  شماره 

صفحات  -

تاریخ انتشار 2012