Computer-assisted quantification of vascular tortuosity in retinopathy of prematurity (an American Ophthalmological Society thesis).

نویسنده

  • David K Wallace
چکیده

PURPOSE Plus disease is severely abnormal dilation and tortuosity of posterior retinal blood vessels in infants with retinopathy of prematurity (ROP). It has become the major criterion for laser treatment in ROP, but its assessment is subjective and prone to error. ROPtool is a computer program that traces retinal blood vessels, measures their tortuosity, and determines whether there is sufficient tortuosity for plus disease. The purpose of this study was to prospectively determine if assessment of tortuosity by ROPtool is more accurate than by individual pediatric ophthalmologists. METHODS One hundred eighty-five high-quality RetCam images from premature infants were circulated to 3 ROP experts to develop reference data and to 3 other pediatric ophthalmologists ("examiners") who graded the tortuosity in each quadrant as normal, pre-plus, or plus. These same images were analyzed using ROPtool. Overall accuracy, sensitivity, and specificity of ROPtool relative to expert consensus were compared to that of the individual examiners. RESULTS By expert consensus, 37 of the 185 eyes (20%) had tortuosity sufficient for plus disease. The overall accuracy of ROPtool of 95% (175/185) for identifying tortuosity sufficient for plus disease was similar to that of examiner 1 (93%, 172/185, P = .5), examiner 2 (93%, 172/185, P = .5), and examiner 3 (91%, 168/185, P = .1). Sensitivity of ROPtool of 97% (36/37) was superior to that of examiner 1 (65%, 24/37, P < .001), examiner 2 (70%, 26/37, P < .001), and examiner 3 (81%, 30/37, P = .02). The mean tortuosity of quadrants with plus disease was 19.1 tortuosity units, compared to 9.9 tortuosity units for quadrants with pre-plus (P < .001) and 4.8 tortuosity units for normal quadrants (P < .001 for pre-plus vs normal). CONCLUSIONS ROPtool has excellent sensitivity and overall accuracy relative to expert consensus in the detection of tortuosity sufficient for plus disease. Computer-assisted analysis of retinal images has the potential to remove subjectivity from the determination of plus disease and to optimize the timing of follow-up and treatment for ROP.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Semiautomated digital image analysis of posterior pole vessels in retinopathy of prematurity.

Plus disease is a major indicator for treatment in retinopathy of prematurity (ROP), and computer-assisted image analysis of vessel caliber and tortuosity in the posterior pole may indicate disease progression and severity. We sought to determine whether semiautomated digital analysis of posterior pole vessels using narrow field images with varying severity of ROP correlated with vessel width a...

متن کامل

Computer-Assisted Digital Image Analysis of Plus Disease in Retinopathy of Prematurity.

The objective of this study is to review the current state and role of computer-assisted analysis in diagnosis of plus disease in retinopathy of prematurity. Diagnosis and documentation of retinopathy of prematurity are increasingly being supplemented by digital imaging. The incorporation of computer-aided techniques has the potential to add valuable information and standardization regarding th...

متن کامل

Studies on the pathogenesis of avascular retina and neovascularization into the vitreous in peripheral severe retinopathy of prematurity (an american ophthalmological society thesis).

PURPOSE To study vascular endothelial growth factor (VEGF) regulation in the development of intravitreous neovascularization and peripheral avascular retina in peripheral severe retinopathy of prematurity (ROP). METHODS The rat 50/10 model of ROP mimics zone II, stage 3 severe ROP and recreates fluctuations in transcutaneous oxygen levels in preterm infants. On postnatal (p) day ages p0, p8, ...

متن کامل

Accuracy of ROPtool vs individual examiners in assessing retinal vascular tortuosity.

OBJECTIVE To prospectively determine if tortuosity assessment by a computer program (ROPtool) that traces retinal blood vessels and measures their tortuosity was more accurate than that of individual pediatric ophthalmologists. METHODS One hundred eighty-five high-quality RetCam images from premature infants were circulated to 3 retinopathy of prematurity (ROP) experts and 3 other pediatric o...

متن کامل

Computer-assisted measurement of retinal vascular width and tortuosity in retinopathy of prematurity.

OBJECTIVES To validate the accuracy of ROPtool software in measuring retinal vascular width and tortuosity in a large image set compared with expert diagnoses. METHODS Tortuosity and dilation indexes generated by ROPtool were compared with 3 expert consensus grades of normal, pre-plus, or plus disease for 368 quadrants in 92 RetCam (Clarity Medical Systems, Pleasanton, California) fundus imag...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Transactions of the American Ophthalmological Society

دوره 105  شماره 

صفحات  -

تاریخ انتشار 2007