Continuum damage model for bioresorbable magnesium alloy devices - Application to coronary stents.
نویسندگان
چکیده
The main drawback of a conventional stenting procedure is the high risk of restenosis. The idea of a stent that "disappears" after having fulfilled its mission is very intriguing and fascinating, since it can be expected that the stent mass decreases in time to allow the gradual transmission of the mechanical load to the surrounding tissues owing to controlled dissolution by corrosion. Magnesium and its alloys are appealing materials for designing biodegradable stents. The objective of this work is to develop, in a finite element framework, a model of magnesium degradation that is able to predict the corrosion rate, thus providing a valuable tool for the design of bioresorbable stents. Continuum damage mechanics is suitable for modeling several damage mechanisms, including different types of corrosion. In this study, the damage is assumed to be the superposition of stress corrosion and uniform microgalvanic corrosion processes. The former describes the stress-mediated localization of the corrosion attack through a stress-dependent evolution law, while the latter affects the free surface of the material exposed to an aggressive environment. Comparisons with experimental tests show that the developed model can reproduce the behavior of different magnesium alloys subjected to static corrosion tests. The study shows that parameter identification for a correct calibration of the model response on the results of uniform and stress corrosion experimental tests is reachable. Moreover, three-dimensional stenting procedures accounting for interaction with the arterial vessel are simulated, and it is shown how the proposed modeling approach gives the possibility of accounting for the combined effects of an aggressive environment and mechanical loading.
منابع مشابه
Bioresorbable Drug-Eluting Magnesium-Alloy Scaffold for Treatment of Coronary Artery Disease
The introduction of metallic drug-eluting stents has reduced the risk of restenosis and widened the indications of percutaneous coronary intervention in treatment of coronary artery disease. However, this medical device can induce hypersensitive reaction that interferes with the endothelialization and healing process resulting in late persistent or acquired malapposition of the permanent metall...
متن کاملEvaluation of continuum damage at different temperatures for aluminum-silicon alloy of engine piston within low-cycle fatigue regime
In this article, the isothermal low-cycle fatigue continuum damage in the engine piston aluminum alloy has been evaluated at different temperatures. For this objective, experimental data of low-cycle fatigue tests on standard specimens were used at 280, 350 and 425°C. Based on the continuum damage mechanics method, the fatigue damage was calculated during cyclic loading. Obtained results, inclu...
متن کاملUltra-low-dose hybrid single photon emission computed tomography and coronary computed tomography angiography: a comprehensive and non-invasive diagnostic workup of suspected coronary artery disease.
tion 2015;10:1160–1168. 13. Verheye S, Ormiston JA, Stewart J, Webster M, Sanidas E, Costa R, Costa JR Jr, Chamie D, Abizaid AS, Pinto I, Morrison L, Toyloy S, Bhat V, Yan J, Abizaid A. A next-generation bioresorbable coronary scaffold system: from bench to first clinical evaluation: 6and 12-month clinical and multimodality imaging results. JACC Cardiovasc Interv 2014;7:89–99. 14. Maeng M, Jens...
متن کاملMagnesium alloy covered stent for treatment of a lateral aneurysm model in rabbit common carotid artery: An in vivo study
Magnesium alloy covered stents have rarely been used in the common carotid artery (CCA). We evaluated the long-term efficacy of magnesium alloy covered stents in a lateral aneurysm model in rabbit CCA. Magnesium alloy covered stents (group A, n = 7) or Willis covered stents (group B, n = 5) were inserted in 12 New Zealand White rabbits and they were followed up for 12 months. The long-term feas...
متن کاملCoronary Bioresorbable Vascular Scaffold Use in the Treatment of Coronary Artery Disease.
Bioresorbable vascular scaffolds (BVS) represent a promising novel approach for the treatment of coronary artery disease. BVS promise to address some of the well-known limitations of current drug-eluting stents, while providing a transient scaffolding of the vessel to prevent acute vessel closure/recoil. Drug elution by BVS prevents neointimal proliferation in a similar fashion to drug-eluting ...