Theoretical foundation for real‐time prostate localization using an inductively coupled transmitter and a superconducting quantum interference device (SQUID) magnetometer system
نویسنده
چکیده
Real-time, 3D localization of the prostate for intensity-modulated radiotherapy can be accomplished with passively charged radio frequency transmitters and superconducting quantum interference device (SQUID) magnetometers. The overall system design consists of an external dipole antenna as a power source for charging a microchip implant transmitter and SQUID magnetometers for signal detection. An external dipole antenna charges an on-chip capacitor through inductive coupling in the near field region through a small implant inductor. The charge and discharge sequence between the external antenna and the implant circuit can be defined by half duplex, full duplex, or sequential operations. The resulting implant discharge current creates an alternating magnetic field through the inductor. The field is detected by the surrounding magnetometers, and the location of the implant transmitter can be calculated. Problems associated with this system design are interrelated with the signal strength at the detectors, detector sensitivity, and charge time of the implant capacitor. The physical parameters required for optimizing the system for real-time applications are the operating frequency, implant inductance and capacitance, the external dipole current and loop radius, the detector distance, and mutual inductance. Consequently, the sequential operating mode is the best choice for real-time localization for constraints requiring positioning within 1 s due to the mutual inductance and detector sensitivity. We present the theoretical foundation for designing a real-time, 3D prostate localization system including the associated physical parameters and demonstrate the feasibility and physical limitations for such a system.
منابع مشابه
Magnetic Flux Fluctuations Due to Eddy Currents and Thermal Noise in Metallic Disks
We derive expressions for the magnetic flux in a circular loop due to eddy currents and thermal noise in coaxial metallic disks. The eddy currents are induced by an applied field that changes sinusoidally in time. We give expressions for the eddy current noise when the frequency of the applied field is very low as well as when it is very high. We combine these expressions to obtain one that is ...
متن کاملNoninvasive Measurement of Gastric Propagation Using a Squid Magnetometer
A vector Superconducting QUuntum Interference Device (SQUID} magnetometer wus used to meusure the magnetic fields nssociated with propagation of gustric electrical uctivity. Measurements of the magnetic field vector were consistent with the presumed pattern of current propagation in the gastric musculature. Further studies using two SQUID systems ullowed the first noninvasive determination of t...
متن کاملMeasurement of high spatial resolution magnetocardiogram and source localization in rats with occlusion
In recent years, magnetocardiographic (MCG) source imaging has been implemented for the pathological studies of myocardial diseases. Many clinical studies on infarctions in humans were carried out [1]. A few studies, however, have reported on the in vivo experiments of basic myocardial diseases. Cohen [2] studied the ST sift and the DC shift of a dog's MCG, which were measured after an induced ...
متن کاملA compact, high performance atomic magnetometer for biomedical applications.
We present a highly sensitive room-temperature atomic magnetometer (AM), designed for use in biomedical applications. The magnetometer sensor head is only 2 × 2 × 5 cm3 and is constructed using readily available, low-cost optical components. The magnetic field resolution of the AM is <10 fT Hz–1/2, which is comparable to cryogenically cooled superconducting quantum interference device (SQUID) m...
متن کاملHigh-resolution scanning SQUID microscope
We have combined a novel low temperature positioning mechanism with a single-chip miniature superconducting quantum interference device ~SQUID! magnetometer to form an extremely sensitive new magnetic microscope, with a demonstrated spatial resolution of ;10 mm. The design and operation of this scanning SQUID microscope will be described. The absolute calibration of this instrument with an idea...
متن کامل