Image based cardiac acceleration map using statistical shape and 3D+t myocardial tracking models; in-vitro study on heart phantom
نویسندگان
چکیده
It has been demonstrated that the acceleration signal has potential to monitor heart function and adaptively optimize Cardiac Resynchronization Therapy (CRT) systems. In this paper, we propose a non-invasive method for computing myocardial acceleration from 3D echocardiographic sequences. Displacement of the myocardium was estimated using a two-step approach: (1) 3D automatic segmentation of the myocardium at end-diastole using 3D Active Shape Models (ASM); (2) propagation of this segmentation along the sequence using non-rigid 3D+t image registration (temporal di↵eomorphic free-form-deformation, TDFFD). Acceleration was obtained locally at each point of the myocardium from local displacement. The framework has been tested on images from a realistic physical heart phantom (DHP-01, Shelley Medical Imaging Technologies, London, ON, CA) in which the displacement of some control regions was known. Good correlation has been demonstrated between the estimated displacement function from the algorithms and the phantom setup. Due to the limited temporal resolution, the acceleration signals are sparse and highly noisy. The study suggests a non-invasive technique to measure the cardiac acceleration that may be used to improve the monitoring of cardiac mechanics and optimization of CRT.
منابع مشابه
Evaluation of attenuation correction process in cardiac SPECT images
Introduction: Attenuation correction is a useful process for improving myocardial perfusion SPECT and is dependent on activity and distribution of attenuation coefficients in the body (attenuation map). Attenuation artifacts are a common problem in myocardial perfusion SPECT. The aim of this study was to compare the effect of attenuation correction using different a...
متن کاملRelationship between the optimum cut off frequency for Butterworth filter and lung-heart ratio in 99mTc myocardial SPECT
Background: We investigated whether the lungheart ratio parameter (LHR) can be used to identify the optimum cut off frequency for Butterworth filter in 99mTc myocardial SPECT imaging. Materials and Methods: This study involved a cardiac phantom system consisting of cardiac insert in which 1.10 cm cold defect was inserted into its myocardium wall and filled with 4.0 μCi/ml (0.148 MBq/ml...
متن کاملSimultaneous Segmentation and Motion Recovery in 3D Cardiac Image Analysis
Accurate and robust estimation of the three-dimensional left ventricular geometry and deformation has important clinical implications for better diagnosis and understanding of ischemic heart diseases. So far, most image analysis efforts have performed the shape recovery and the motion tracking tasks in separate steps, typically in sequential fashion. In this paper, we present a continuum biomec...
متن کاملPrediction of long-term cardiac events by 123I-MIBG imaging after acute myocardial infarction and reperfusion therapy
Objective(s): In heart failure, the heart-to-mediastinum (H/M) ratio of the delayed image and washout rate (WR) are well-known as a powerful cardiac event predictors. H/M ratio quantifies the accumulation rate of MIBG in the myocardium and WR quantifies reduction of meta-iodobenzylguanidine (MIBG) accumulation in the heart from the early planar image to the delayed pla...
متن کاملA Statistical Model-Based Approach for the Automatic Quantitative Analysis of Perfusion Gated SPECT Studies
In this paper we present a statistical model-based approach to three-dimensional (3D) analysis of gated SPECT perfusion studies. By means of a 3D Active Shape Model (3D-ASM) segmentation algorithm, delineations of the endoand epicardial borders of the left ventricle are obtained, in all temporal phases and image slices of the study. Prior knowledge was captured from a training set of cardiac MR...
متن کامل