Temperature monitoring during radiofrequency catheter ablation of accessory pathways.

نویسندگان

  • J J Langberg
  • H Calkins
  • R el-Atassi
  • M Borganelli
  • A Leon
  • S J Kalbfleisch
  • F Morady
چکیده

BACKGROUND Animal studies have suggested that the temperature of the electrode-tissue interface during radiofrequency catheter ablation accurately predicts lesion size. The purpose of the current study was to evaluate the utility of continuous temperature monitoring during radiofrequency catheter ablation in patients with Wolff-Parkinson-White syndrome. METHODS AND RESULTS Twenty patients with manifest preexcitation were included in the study. The ablation catheter was positioned on the ventricular side of the mitral annulus for left-sided accessory pathways and on the atrial side of the tricuspid annulus for right-sided and septal accessory pathways. A thermistor imbedded in the distal electrode of the ablation catheter allowed continuous temperature monitoring during each energy application. To define the relation between power and temperature, radiofrequency current was applied several times at each site using outputs of 20, 30, 40, and 50 W. The accessory pathways were successfully ablated in each of the 20 patients. Because of marked variability in the efficiency of heating between sites, power output did not predict temperature. However, at any given site, there was a positive dose-response relation between power and temperature. Radiofrequency energy applications on the atrial side of the tricuspid annulus produced lower temperatures than did applications on the ventricular side of the mitral annulus (49 +/- 7 versus 60 +/- 16 degrees C, p = 0.0001). Transient block in the accessory pathways occurred at a mean of 50 +/- 8 degrees C, whereas permanent block was seen at a mean of 62 +/- 15 degrees C (p = 0.0001). Less than half of the applications at outputs < or = 40 W produced temperatures adequate to interrupt accessory pathway conduction. An abrupt rise in impedance caused by coagulum formation occurred only at temperatures between 95 and 100 degrees C. CONCLUSIONS Temperature monitoring may facilitate radiofrequency catheter ablation of accessory pathways. By adjusting power output to ensure that adequate but not excessive temperatures have been achieved, a rise in impedance can be avoided and the total number of energy applications and procedure duration may be reduced.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Radiofrequency catheter ablation in the treatment of Wolff-Parkinson-White syndrome

Introduction: Tachyarrhythmias in Wolf Parkinson White (WPW) syndrome, can be a life threatening factor. Antiarrhythmic drug therapy in this syndrome, has not been completely acceptable. Efficacy, safety and economy of Radio Frequency Catheter Ablation (RFCA) in western studies, has made it as the treatment of choice. In the present study, efficacy of RFCA in the ablation of accessory pathway...

متن کامل

Catheter Ablation of Accessory Pathways

Background. Animal studies have suggested that the temperature of the electrode-tissue interface during radiofrequency catheter ablation accurately predicts lesion size. The purpose of the current study was to evaluate the utility of continuous temperature monitoring during radiofrequency catheter ablation in patients with Wolff-Parkinson-White syndrome. Methods and Results. Twenty patients wit...

متن کامل

Temperature-controlled radiofrequency catheter ablation of manifest accessory pathways.

OBJECTIVES The primary objectives of this study were to assess the feasibility of temperature-controlled radiofrequency catheter ablation of left and right sided manifest accessory pathways in patients with Wolff-Parkinson-White syndrome and to gain more insights into biophysical aspects of temperature-controlled catheter ablation in humans. BACKGROUND The electrode-tissue interface temperatu...

متن کامل

Randomized comparison of two techniques for titrating power during radiofrequency ablation of accessory pathways.

INTRODUCTION The purpose of this study was to prospectively compare the value of impedance and temperature monitoring during accessory pathway ablation. Temperature and impedance monitoring can be used during radiofrequency ablation of accessory pathways to titrate power to achieve adequate but not excessive tissue heating. METHODS AND RESULTS One hundred thirty-two patients with a single acc...

متن کامل

Temperature-Guided Radiofrequency Catheter Ablation of Accessory Pathway

OBJECTIVES This study was performed to evaluate the usefulness of temperature-guided radiofrequency catheter ablation for the elimination of accessory pathway conduction in patients with Wolff-Parkinson-White syndrome. METHODS Temperature-guided radiofrequency catheter ablation was attempted in 138 patients with 144 accessory pathways (88 pathways along the left free wall, 5 in the anterosept...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Circulation

دوره 86 5  شماره 

صفحات  -

تاریخ انتشار 1992