Importance of polyethylene thickness in total shoulder arthroplasty: a finite element analysis.

نویسندگان

  • Alexandre Terrier
  • Vittoria Brighenti
  • Dominique P Pioletti
  • Alain Farron
چکیده

BACKGROUND Articular surfaces reconstruction is essential in total shoulder arthroplasty. Because of the limited glenoid bone support, thin glenoid component could improve anatomical reconstruction, but adverse mechanical effects might appear. METHODS With a numerical musculoskeletal shoulder model, we analysed and compared three values of thickness of a typical all-polyethylene glenoid component: 2, 4 (reference) and 6mm. A loaded movement of abduction in the scapular plane was simulated. We evaluated the humeral head translation, the muscle moment arms, the joint force, the articular contact pattern, and the polyethylene and cement stress. Findings Decreasing polyethylene thickness from 6 to 2mm slightly increased humeral head translation and muscle moment arms. This induced a small decreased of the joint reaction force, but important increase of stress within the polyethylene and the cement mantel. Interpretation The reference thickness of 4mm seems a good compromise to avoid stress concentration and joint stuffing.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Finite Element Studies on Friction Stir Welding Processes of Polyethylene Plates

One of the interesting state-of-the-art approaches to welding is the process of friction stir welding (FSW). In comparison with the fusion processes, FSW is an advantageous method as it is suitable for the non-fusion weldable alloys and polymeric materials joining. Regarding the materials pure solid state joining, it also provides joints with less distortion and enhanced mechanical properties. ...

متن کامل

Effects of Tibial Insert Slope on Polyethylene Wear and Stress

INTRODUCTION: Both posterior stabilized (PS) and cruciate retaining (CR) total knee replacement systems have demonstrated high rates of survivorship, high clinical knee scores and high patient satisfaction scores for decades. However, CR total knees sometimes exhibit more varied kinematics and a smaller range of motion than similar PS knees. Many factors can cause this, but one important factor...

متن کامل

Stress analysis of glenoid component designs for shoulder arthroplasty.

Secure and lasting fixation of the glenoid component in total shoulder arthroplasty is difficult because there is an insufficient volume of strong bone in the scapula. Consequently, radiolucencies of the glenoid component are common (much more common than radiolucencies of the humeral component). Early glenoid component designs were fabricated wholly from polyethylene, were fixated with PMMA ce...

متن کامل

Contact stress assessment of conventional and highly crosslinked ultra high molecular weight polyethylene acetabular liners with finite element analysis and pressure sensitive film.

Stress magnitude and distribution of both conventional polyethylene versus a crosslinked polyethylene in the liner of a total hip replacement (THR) were examined using finite element analysis and pressure sensitive film. Both types of polyethylene were assessed against head sizes of 22 and 28 mm with 5-mm thick polyethylene liners and head sizes of 28, 38, and 46 mm with 3-mm thick polyethylene...

متن کامل

Development and Validation of a Wear Model to Predict Polyethylene Wear in a Total Knee Arthroplasty: A Finite Element Analysis

Ultra-high molecular weight polyethylene (UHMWPE) wear in total knee arthroplasty (TKA) components is one of the main reasons of the failure of implants and the consequent necessity of a revision procedure. Experimental wear tests are commonly used to quantify polyethylene wear in an implant, but these procedures are quite expensive and time consuming. On the other hand, numerical models could ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical biomechanics

دوره 27 5  شماره 

صفحات  -