Learning effect of humphrey matrix frequency doubling technology perimetry in patients with ocular hypertension.

نویسندگان

  • Marco Centofanti
  • Paolo Fogagnolo
  • Francesco Oddone
  • Nicola Orzalesi
  • Michele Vetrugno
  • Gianluca Manni
  • Luca Rossetti
چکیده

AIM To evaluate the learning effect of Frequency Doubling Technology (FDT) perimetry using the Humphrey Matrix-FDT perimetry (Matrix) 24-2 full-threshold program on patients with ocular hypertension experienced with standard automated perimetry. METHODS Twenty-four patients with ocular hypertension underwent 5 full-threshold Matrix tests at intervals of 5+/-2 days. Learning effect was defined as an improvement at results for duration, perimetric indices, foveal sensitivity, Glaucoma Hemifield Test, and the number of points with a P<5% and <1% in the total and pattern deviation maps. Eccentricity, hemifield, and quadrant sensitivities were also addressed as sources of differences in learning effect. Test-retest variability was also calculated for each repetition as the mean of the point-to-point interindividual standard deviations. RESULTS A learning effect was demonstrated for mean defect (P=0.031, analysis of variance) and foveal sensitivity (P=0.009) and it only affected the first test for both parameters. All the other parameters did not show any significant learning effect. The effect was independent from eccentricity and quadrant or hemifield sensitivities. CONCLUSIONS The results of this study demonstrate that the learning effect for Matrix-FDT is mild and it may affect only the first test. Caution is needed in the analysis of the first Matrix-FDT examination and retest may be advisable in the presence of low mean defect.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Frequency Doubling Technology vs Standard Automated Perimetry in Ocular Hypertensive Patients

BACKGROUND Frequency doubling technology (FDT) perimetry measures contrast sensitivity. The magnocellular component of ganglion cells in human retina is isolated as a whole by the FDT stimulus. The aim of this study is to investigate the role of Humphrey Matrix threshold testing in the detection of early functional retinal impairment in ocular hypertensive patients compared to standard automate...

متن کامل

Screening for glaucoma with frequency-doubling technology and Damato campimetry.

OBJECTIVE To assess frequency-doubling technology (FDT) perimetry (Humphrey Systems, San Leandro, Calif) and Damato campimetry (Precision Vision, Villa Park, Ill) for detecting glaucoma in a public glaucoma screening. METHODS A 2-day public glaucoma screening was held at 2 different institutions. Each subject underwent 2 visual field screening tests (Damato campimetry and FDT perimetry in scr...

متن کامل

Clinical comparison of frequency doubling technology perimetry and Humphrey perimetry.

AIM To determine the number of missed points on frequency doubling technology (FDT) perimetry that optimise the sensitivity and specificity of the test and to determine the topographical accuracy of the test in a clinical setting. METHODS In a prospective study, the perimetric data from 99 patients who underwent both FDT perimetry in the screening mode and Humphrey 24-2 (H24-2) were used to d...

متن کامل

Comparison of visual field test results obtained through Humphrey matrix frequency doubling technology perimetry versus standard automated perimetry in healthy children

AIMS The aim of this study was to compare the visual field test results in healthy children obtained via the Humphrey matrix 24-2 threshold program and standard automated perimetry (SAP) using the Swedish interactive threshold algorithm (SITA)-Standard 24-2 test. MATERIALS AND METHODS This prospective study included 55 healthy children without ocular or systemic disorders who underwent both S...

متن کامل

A comparison of perimetric results with the Medmont and Humphrey perimeters.

BACKGROUND The Humphrey field analyser (HFA), Humphrey-Zeiss frequency doubling perimeter, and the Medmont automated perimeter (MAP) are three commonly used automated perimeters with threshold achromatic methodologies. Visual field loss may be detected earlier with strategies that target cell lines with reduced redundancy or which suffer selective damage. METHOD To compare these three perimet...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of glaucoma

دوره 17 6  شماره 

صفحات  -

تاریخ انتشار 2008