Correlation of intravascular ultrasound findings with histopathological analysis of thrombus aspirates in patients with very late drug-eluting stent thrombosis.

نویسندگان

  • Stéphane Cook
  • Elena Ladich
  • Gaku Nakazawa
  • Parham Eshtehardi
  • Michel Neidhart
  • Rolf Vogel
  • Mario Togni
  • Peter Wenaweser
  • Michael Billinger
  • Christian Seiler
  • Steffen Gay
  • Bernhard Meier
  • Werner J Pichler
  • Peter Jüni
  • Renu Virmani
  • Stephan Windecker
چکیده

BACKGROUND Intravascular ultrasound of drug-eluting stent (DES) thrombosis (ST) reveals a high incidence of incomplete stent apposition (ISA) and vessel remodeling. Autopsy specimens of DES ST show delayed healing and hypersensitivity reactions. The present study sought to correlate histopathology of thrombus aspirates with intravascular ultrasound findings in patients with very late DES ST. METHODS AND RESULTS The study population consisted of 54 patients (28 patients with very late DES ST and 26 controls). Of 28 patients with very late DES ST, 10 patients (1020+/-283 days after implantation) with 11 ST segments (5 sirolimus-eluting stents, 5 paclitaxel-eluting stents, 1 zotarolimus-eluting stent) underwent both thrombus aspiration and intravascular ultrasound investigation. ISA was present in 73% of cases with an ISA cross-sectional area of 6.2+/-2.4 mm(2) and evidence of vessel remodeling (index, 1.6+/-0.3). Histopathological analysis showed pieces of fresh thrombus with inflammatory cell infiltrates (DES, 263+/-149 white blood cells per high-power field) and eosinophils (DES, 20+/-24 eosinophils per high-power field; sirolimus-eluting stents, 34+/-28; paclitaxel-eluting stents, 6+/-6; P for sirolimus-eluting stents versus paclitaxel-eluting stents=0.09). The mean number of eosinophils per high-power field was higher in specimens from very late DES ST (20+/-24) than in those from spontaneous acute myocardial infarction (7+/-10), early bare-metal stent ST (1+/-1), early DES ST (1+/-2), and late bare-metal stent ST (2+/-3; P from ANOVA=0.038). Eosinophil count correlated with ISA cross-sectional area, with an average increase of 5.4 eosinophils per high-power field per 1-mm(2) increase in ISA cross-sectional area. CONCLUSIONS Very late DES thrombosis is associated with histopathological signs of inflammation and intravascular ultrasound evidence of vessel remodeling. Compared with other causes of myocardial infarction, eosinophilic infiltrates are more common in thrombi harvested from very late DES thrombosis, particularly in sirolimus-eluting stents, and correlate with the extent of stent malapposition.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Latest on the pathology of drug-eluting stents

The introduction of drug-eluting stents (DES) has significantly reduced restenosis when compared with bare-metal stents and are considered the standard of care in the treatment of symptomatic coronary artery disease. However, late stent thrombosis (LST), potentially resulting in a fatal occlusion of the vessel, emerged as a major concern in first-generation DES (polymer-based sirolimusand pacli...

متن کامل

Plasma brain natriuretic peptide-guided therapy not yet justified.

1. Iakovow I, Schmidt T, Bonizzoni E, et al. Incidence, predictors and outcome of thrombosis after successful implantation of drug-eluting stents. JAMA 2005;293:2126–30. 2. Kuchulakanti PK, Chu WW, Torguson R, et al. Correlates and long-term outcomes of angiographically proven stent thrombosis with sirolimus and paclitaxel-eluting stents. Circulation 2006;113; 1108 –13. 3. Alfonso F, Suarez A, ...

متن کامل

Association of Localized Hypersensitivity and In-Stent Neoatherosclerosis with the Very Late Drug-Eluting Stent Thrombosis

BACKGROUND Localized hypersensitivity reaction, delayed arterial healing, and neoatherosclerosis inside the stent have been suggested as the underlying pathologic mechanisms of very late stent thrombosis (VLST) of drug-eluting stent (DES). The present study sought to explore the prevalence of inflammatory cell infiltrates and evidence for fragments of atherosclerotic plaques in the aspirated th...

متن کامل

Incomplete stent apposition and very late stent thrombosis after drug-eluting stent implantation.

BACKGROUND Stent thrombosis may occur late after drug-eluting stent (DES) implantation, and its cause remains unknown. The present study investigated differences of the stented segment between patients with and without very late stent thrombosis with the use of intravascular ultrasound. METHODS AND RESULTS Since January 2004, patients presenting with very late stent thrombosis (> 1 year) afte...

متن کامل

Pathological Perspective of Drug-Eluting Stent Thrombosis

Although very late stent thrombosis (VLST) after drug-eluting stent (DES) implantation remains a major concern, the precise mechanisms have not been clarified. An association between late acquired incomplete stent apposition (ISA) and VLST of DES has been suggested by several intravascular ultrasound studies demonstrating very high prevalence of ISA in the setting of VLST. To clarify the pathol...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Circulation

دوره 120 5  شماره 

صفحات  -

تاریخ انتشار 2009