New Dacron tissue colonisable keratoprosthesis: clinical experience.

نویسندگان

  • S Pintucci
  • F Pintucci
  • M Cecconi
  • S Caiazza
چکیده

BACKGROUND Keratoprostheses (KPs) are made of an optical cylinder integrated with a supporting element which conditions their biocompatibility. A new KP with a Dacron tissue colonisable support has been designed in order to reduce significantly the complication rate. METHODS This new KP was implanted into 20 eyes of 20 patients with bilateral corneal blindness unsuited to a corneal implant. The follow up ranged from 24 to 96 months. RESULTS All 20 patients had some improved visual acuity with 13 retaining this improvement for more than 2 years. CONCLUSION These favourable results may be indicative of the reliability of the new KP.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Boston type 1 keratoprosthesis from patient selection through postoperative management: a review for the keratoprosthetic surgeon

For the anterior segment surgeon, the implantation of Boston type 1 keratoprosthesis is a multistep process that begins with careful patient selection. Success depends on thorough preoperative evaluation, detailed surgical planning, and frequent postoperative follow-up. New practice patterns have emerged for each of these phases as the international experience with keratoprosthesis grows. This ...

متن کامل

Boston type 1 keratoprosthesis: the university of california davis experience.

PURPOSE To compare the University of California Davis experience using the Boston keratoprosthesis with the Boston Keratoprosthesis Study Group's initial report. DESIGN Retrospective chart review. PARTICIPANTS We analyzed 30 eyes of 28 patients who previously underwent Boston type 1 keratoprosthesis surgery at our institution between 2004 and 2008. METHODS Preoperative, intraoperative, an...

متن کامل

Improved centration of the type 1 Boston Keratoprosthesis in donor carrier tissue

The type 1 Boston Keratoprosthesis preparation requires a 3-mm central punch and an 8.5 mm or larger punch in the carrier tissue. These punches are ideally concentric, but we have found difficulty in achieving concentric punches when the larger punch is performed first. We present a modification in the preparation procedure to help minimize centration error.

متن کامل

Osteo-Odonto Keratoprosthesis (OOKP): A Review of Surgical Techniques and Clinical Outcomes

Osteo-odonto keratoprosthesis (OOKP) is a multi-staged procedure for the treatment of blindness due to bilateral severe endstage corneal disease. Developed by Strampelli over fifty years ago and modified thereafter by Falcinelli, the OOKP is by far the only keratoprosthesis that has been retained in eyes for over twenty to thirty years. This procedure can be performed in eyes with bone dry and ...

متن کامل

Boston type I keratoprosthesis-donor cornea interface evaluated by high-definition spectral-domain anterior segment optical coherence tomography

BACKGROUND The purpose of this study was to assess whether the resolution offered by two different, recently commercially available high-resolution, spectral-domain anterior segment optical coherence tomography (AS-OCT) instruments allows for detailed anatomic characterization of the critical device-donor cornea interface in eyes implanted with the Boston type I permanent keratoprosthesis. ME...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The British journal of ophthalmology

دوره 79 9  شماره 

صفحات  -

تاریخ انتشار 1995