Diagnosis and Anti-Reflux Therapy for GERD with Respiratory Symptoms: A Study Using Multichannel Intraluminal Impedance-pH Monitoring

نویسندگان

  • Chao Zhang
  • Jimin Wu
  • Zhiwei Hu
  • Chao Yan
  • Xiang Gao
  • Weitao Liang
  • Diangang Liu
  • Fei Li
  • Zhonggao Wang
چکیده

BACKGROUND/AIMS Respiratory symptoms are often associated with gastroesophageal reflux disease (GERD). Although the role of multichannel intraluminal impedance-pH (MII-pH) monitoring in GERD is clear, little is known regarding the characteristics of patients with respiratory symptoms based on MII-pH monitoring and anti-reflux therapy. We evaluated a cohort of GERD patients to identify the MII-pH parameters of GERD-related respiratory symptoms and to assess the anti-reflux therapy outcomes. METHODS We undertook a prospective study of patients who were referred for GERD evaluation from January 2011 to January 2012. One hundred ninety-five patients underwent MII-pH monitoring and esophageal manometry, and one hundred sixty-five patients underwent invasive anti-reflux therapy that included laparoscopic Toupet fundoplication (LTF) and the Stretta procedure. The patient characteristics and MII-pH parameters were analyzed, and the symptom scores were assessed at baseline and at 1- and 3-year follow-up evaluations. RESULTS Of the 195 patients, 96 (49.2%) exhibited respiratory symptoms and significantly more reflux episodes (70.7±29.3) than patients without respiratory symptoms (64.7±24.4, p = 0.044) based on the MII-pH monitoring results. Moreover, the group of patients with respiratory symptoms exhibited more proximal reflux episodes (35.2±21.3) than the non-respiratory symptomatic group (28.3±17.9, p = 0.013). One hundred twenty-five patients following the Stretta procedure (n = 60, 31 with respiratory symptoms) or LTF (n = 65, 35 with respiratory symptoms) completed the designated 3-year follow-up period and were included in the final analysis. The symptom scores after anti-reflux therapy all decreased relative to the corresponding baseline values (p<0.05), and there were no significant differences in the control of respiration between the Stretta procedure and LTF (p>0.05). However, LTF significantly reduced the recurrence (re-operation) rate compared with the Stretta procedure (0 vs. 19.4%, p = 0.006). CONCLUSIONS MII-pH monitoring effectively detected respiratory-related predictive parameters, including total/proximal reflux episodes and symptom correlations. We found that GERD patients with respiratory symptoms exhibited more proximal and total reflux episodes but not more acid-related episodes, as determined by MII-pH monitoring. Thus, such monitoring could be useful for diagnosing atypical GERD patients with respiratory symptoms. Furthermore, LTF exhibited a more significant effect on controlling typical symptoms in all GERD patients and reducing the recurrence rate than the Stretta procedure in patients with respiratory symptoms.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Multichannel intraluminal impedance and pH-metry for investigation of symptomatic gastroesophageal reflux disease.

BACKGROUND Combined multichannel intraluminal impedance and pH-metry (MII-pH) is a technique that enables monitoring of gastroesophageal reflux independent of its acidity. AIM To investigate the utility of MII-pH in the clinical investigation of patients with gastroesophageal reflux disease (GERD) symptoms. METHODS 32 consecutive patients underwent 24-hour ambulatory MII-pH. 16 patients wer...

متن کامل

Combined pH-metry/impedance monitoring increases the diagnostic yield in patients with atypical gastroesophageal reflux symptoms.

BACKGROUND Globus sensations, hoarseness and chronic cough are suggested to be atypical manifestations of Gastroesophageal Reflux Disease (GERD). The aim of the study was to investigate whether combined pH-metry and multichannel intraluminal impedance monitoring increases the diagnostic yield. METHODS 41 patients with atypical GERD symptoms were included in the study. Globus sensation was the...

متن کامل

Diagnostic difficulties during combined multichannel intraluminal impedance and pH monitoring in patients with esophagitis or Barrett's esophagus.

Gastroesophageal reflux disease (GERD) is one of the most common esophageal diseases in developed countries. It is widely believed that GERD symptoms are caused by acid refluxate within the esophagus, so ambulatory 24 hour pH-monitoring became the gold standard in detecting gastroesophageal reflux. Traditional ambulatory pH monitoring is unable to detect a gastroesophageal reflux with pH >4. Th...

متن کامل

Comparison of multichannel intraluminal impedance-pH monitoring and reflux scintigraphy in pediatric patients with suspected gastroesophageal reflux

AIM To evaluate the agreement of multichannel intraluminal impedance-pH monitoring (MII-pHM) and gastroesophageal reflux scintigraphy (GES) for the diagnosis of gastroesophageal reflux disease. METHODS Seventy-five consecutive patients with suspected gastroesophageal reflux disease (GERD) underwent 24-h combined MII-pHM recording and one hour radionuclide scintigraphy during the course of the...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 11  شماره 

صفحات  -

تاریخ انتشار 2016