A comparison of biventricular and conventional transvenous defibrillation: a computational study using patient derived models.

نویسندگان

  • Daniel Mocanu
  • Joachim Kettenbach
  • Michael O Sweeney
  • Ron Kikinis
  • Bruce H Kenknight
  • Solomon R Eisenberg
چکیده

Conventional transvenous defibrillation is performed with an ICD using a dual current pathway. The defibrillation energy is delivered from the RV electrode to the superior vena cava (SVC) electrode and the metallic case (CAN) of the ICD. Biventricular defibrillation uses an additional electrode placed in the LV free wall with sequential shocks to create an additional current vector. Clinical studies of biventricular defibrillation have reported a 45% reduction in mean defibrillation threshold (DFT) energy. The aim of the study was to use computational methods to examine the biventricular defibrillation fields together with their corresponding DFTs in a variety of patient derived models and to compare them to simulations of conventional defibrillation. A library of thoracic models derived from nine patients was used to solve for electric field distributions. The defibrillation waveform consisted of a LV --> SVC + CAN monophasic shock followed by a biphasic shock delivered via the RV --> SVC + CAN electrodes. When the initial voltage of the two shocks is the same, the simulations show that the biventricular configuration reduces the mean DFT by 46% (3.5 +/- 1.3 vs 5.5 +/- 2.7 J, P = 0.005). When the leading edge of the biphasic shock is equal to the trailing edge of the monophasic shock, there is no statistically significant difference in the mean DFT (4.9 +/- 1.9 vs 5.5 +/- 2.7 J, P > 0.05) with the DFT decreasing in some patients and increasing in others. These results suggest that patient-specific computational models may be able to identify those patients who would most benefit from a biventricular configuration.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Biventricular Defibrillation with Sequential Shocks Using Patient-derived Computational Models

Standard transvenous defibrillation is performed with implantable cardioverter defibrillators (ICD) using a dualcurrent pathway. The defibrillation energy is delivered from the right ventricle (RV) electrode to the superior vena cava (SVC) electrode and the ICD metallic housing. Clinical studies of biventricular defibrillation, which uses an additional electrode, placed on the left ventricular ...

متن کامل

A Patient-specific Computational Study of Transvenous Defibrillation

The goal of this study is to assess the predictive capacity of computational models of transvenous defibrillation by comparing the results of patient-specific simulations to clinically determined defibrillation metrics. Solutions for seven patient-specific models have been completed. The 3-D models of the thorax and in situ electrodes were created from segmented CT images taken shortly after im...

متن کامل

Atrial defibrillation with a transvenous lead: a randomized comparison of active can shocking pathways.

OBJECTIVES The purpose of this study was to compare transvenous atrial defibrillation thresholds with lead configurations consisting of an active left pectoral electrode and either single or dual transvenous coils. BACKGROUND Low atrial defibrillation thresholds are achieved using complex lead systems including coils in the coronary sinus. However, the efficacy of more simple ventricular defi...

متن کامل

Transvenous biventricular defibrillation halves energy requirements in patients.

BACKGROUND Defibrillation thresholds (DFT) with standard implantable cardioverter-defibrillator leads in the right ventricle (RV) may be determined by weak shock field intensity in the myocardium of the left ventricle (LV). Adding a shocking electrode in a coronary vein on the middle of the LV free wall, thereby establishing biventricular defibrillation, substantially reduced defibrillation req...

متن کامل

Ventricular tachycardia initiated by high energy cardioversion in a patient with an implantable cardioverter defibrillator.

A transvenous implantable cardioverter defibrillator (ICD) was implanted into a 58 year old woman with idiopathic dilated cardiomyopathy who had drug refractory monomorphic ventricular tachycardia (VT). Antitachycardia pacing failed to terminate the VT; termination was attempted at 24 J, which was above the defibrillation threshold. When cardioversion at 24 J was delivered, VT with a different ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Pacing and clinical electrophysiology : PACE

دوره 27 5  شماره 

صفحات  -

تاریخ انتشار 2004