Accuracy and precision of noninvasive temperature measurement in adult intensive care patients.

نویسندگان

  • Lari Lawson
  • Elizabeth J Bridges
  • Isabelle Ballou
  • Ruthe Eraker
  • Sheryl Greco
  • Janie Shively
  • Vanessa Sochulak
چکیده

BACKGROUND Research on the accuracy and precision of noninvasive methods of measuring body temperature is equivocal. OBJECTIVES To determine accuracy and precision of oral, ear-based, temporal artery, and axillary temperature measurements compared with pulmonary artery temperature. METHODS Repeated-measures design conducted for 6 months. Sequential temperature measurements on the same side of the body were obtained within 1 minute, with measurements repeated 3 times at 20-minute intervals. Accuracy, precision, and confidence limits were analyzed. RESULTS In 60 adults with cardiopulmonary disease and a pulmonary artery catheter, mean pulmonary artery temperature was 37.1 degrees C (SD 0.6 degrees C, range 35.3 degrees C-39.4 degrees C). Mean (SD) offset from pulmonary artery temperature (with the mean reflecting accuracy and SD reflecting precision) and confidence limits were 0.09 degrees C (0.43 degrees C) and -0.75 degrees C to 0.93 degrees C for oral measurements, -0.36 degrees C (0.56 degrees C) and -1.46 degrees C to 0.74 degrees C for ear measurements, -0.02 degrees C (0.47 degrees C) and -0.92 degrees C to 0.88 degrees C for temporal artery measurements, and 0.23 degrees C (0.44 degrees C) and -0.64 degrees C to 1.12 degrees C for axillary measurements. Percentage of pairs with differences greater than +/-0.5 degrees C was 19% for oral, 49% for ear, 20% for temporal artery, and 27% for axillary measurements. Intubation increased oral measurements compared with pulmonary artery temperatures (mean difference 0.3 degrees C, SD 0.3 degrees C, P = .001). CONCLUSIONS Oral and temporal artery measurements were most accurate and precise. Axillary measurements underestimated pulmonary artery temperature. Ear measurements were least accurate and precise. Intubation affected the accuracy of oral measurements; diaphoresis and airflow across the face may affect temporal artery measurements.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Accuracy and precision of four common peripheral temperature measurement methods in intensive care patients

INTRODUCTION An accurate determination of body temperature in critically ill patients is a fundamental requirement for initiating the proper process of diagnosis, and also therapeutic actions; therefore, the aim of the study was to assess the accuracy and precision of four noninvasive peripheral methods of temperature measurement compared to the central nasopharyngeal measurement. METHODS In ...

متن کامل

بررسی صحت و دقت دمای تمپانیک در بازتاب دمای مرکزی بدن

  Background & Aim: Monitoring of patients' temperature is an important nursing clinical procedure. Body temperature is usually taken at different sites including pulmonary artery, rectal, oral, and axillary areas. Currently, infrared tympanic temperature measurement method is increasingly used as a convenient, noninvasive and rapid method. However, accuracy and precision of this method has bee...

متن کامل

Accuracy of temporal artery thermometry in neonatal intensive care infants.

PURPOSE To determine the accuracy of temporal artery and axillary temperatures and the discomfort level of stable neonates during temperature measurement. SUBJECTS Convenience sample of neonates between the ages of 32 and 40 weeks' gestation cared for in an isolette or crib. DESIGN A method-comparison design was used to compare different methods for noninvasive temperature monitoring (infra...

متن کامل

Comparison sensitivity and specificity temporal artery temperature measurement with axillary and nasopharyngeal methods in adult

      Aims: temporal artery thermometers (TAT) of new tools for measuring body temperature, few studies have been conducted to evaluate the accuracy and reliability of thermometers and is still uncertain accuracy and reliability this thermometers.This study to evaluate the accuracy of the two methods of measuring body temperature by the thermometer axillary and temporal artery compared with nas...

متن کامل

Accuracy of noninvasive and continuous hemoglobin measurement by pulse co-oximetry during preoperative phlebotomy.

BACKGROUND In recent years, the continuous noninvasive hemoglobin measurement has been offered by devices using advanced pulse oximetry technology. Accuracy has been established in healthy adults as well as in surgical and intensive care unit patients but not in the setting of acute hemorrhage. In this study, we evaluated the accuracy of such a device in the clinical setting of preoperative phl...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • American journal of critical care : an official publication, American Association of Critical-Care Nurses

دوره 16 5  شماره 

صفحات  -

تاریخ انتشار 2007