Effect of two-phase fabrication method for the optimum fit of light-polymerized record bases
نویسندگان
چکیده
PURPOSE The aims of this study were to suggest a method of fabrication of the record base using a light-polymerized resin by applying the two-phase fabrication method for the improvement of the fit of the record base and to compare the degree of fit according to the separation site. MATERIALS AND METHODS In the edentulous cast of maxilla, four test groups were considered. In the first, second, third, and fourth test groups (n = 12 in each group) the separation was done at 0, 5, 10, and 15 mm, respectively below the alveolar crest along the palatal plane. For the control group, the record base was made without separating the two sections. The light-body silicone material was injected into the fitting surface of the record base. It was then placed onto the cast and finger pressure was applied to stabilize it in a seated position followed by immediate placement onto the universal test device. Finally, the mass of the impression material was measured after it was removed. ANOVA was performed using the SAS program. For the post-hoc test, the Wilcoxon Rank-Sum test and the Tukey-Kramer HSD test were performed (α = 0.05). RESULTS The control group and Group 3, 4 showed significant differences. The Group 3 and 4 showed significantly smaller inside gaps than the control group which was not made with the two-phase fabrication method. CONCLUSION The two-stage polymerized technique can improve the fit of the denture base particularly when the separation was made at 10 to 15 mm from the alveolar crest.
منابع مشابه
Effect of Stone Cast Type on Complete Denture Base Adaptation
Introduction: Few researches have been conducted researches on the influence of the type of dental stone used for fabrication of casts on the adaptation of denture bases. The purpose of this study was to compare the effect of two types of stone casts on the accuracy of fit in complete denture bases. Methods: Using sixty fully replicated master casts obtained by duplicating a metal die represent...
متن کاملA method for detecting bubbles in two-phase gas-liquid flow
Detecting bubble in two-phase flow has been a basic issue in two-phase flow systems. A new method for measuring the frequency of bubble formation is presented in this paper. For this purpose, an electronic device was designed and constructed which works based on a change in intensity of laser beam. For this purpose, continues light beam is embedded just above the needle, which is received by a ...
متن کاملFabrication of Biodegradable PCL Particles as well as PA66 Nanofibers via Air-Sealed Centrifuge Electrospinning (ASCES)
This study presents a method for fabrication of ultrafine polymeric nanofibers as well as nano/micro particles utilizing centrifugal and electrostatic forces simultaneously. To reduce the diameter and variety of nanofibers produced from solid state polymerized PA66, a unique electrocentrifuge spinning device was utilized with a rotating nozzle and collector, while the fabrication process (spinn...
متن کاملبررسی تأثیر چند روش پلیمریزاسیون بر تغییرات ابعادی آکریل سرماسخت ایرانی (آکروپارس)
Statement of Problem:Iranian product, Acropars autopolymerizing acrylic resin is nowadays widely used in dental prostheses. Dimensional change is a common problem among Iranian made acrylic resins in making custom trays and record bases, seems to be more than the similar foreign products. In order to achieve a technique for making a record base with minimum dimensional changes, more research is...
متن کاملFabrication and evaluation of gelatin nanoparticles for delivering of anti - cancer drug
The aim of present study was to prepare gelatin nanoparticle for drug and gene delivery applications. These nanoparticles were prepared by two-step desolvation method. The body distribution of colloidal drug delivery systems was mainly influenced by two physicochemical properties namely particle size and surface characteristics. The influence of several factors on the fabrication process includ...
متن کامل