Effect of height and weight on the in vivo recovery of transfused factor VIII C.
نویسندگان
چکیده
The in vivo recovery of factor VIII has been estimated on 84 occasions in 53 severely affected adolescent haemophiliacs. There was wide individual variation in recovery, which was not affected by differences in the administered dose. Recovery increased steadily with increasing surface area, and it was only over a surface area of 1.7 m2 that a recovery of 2% of factor VIII per unit per kg became the norm. It is suggested that the only safe assumption to make below that surface area in an in vivo recovery of 1.5%.
منابع مشابه
A prospective Crossover Triple-blind Controlled Trial on the Safety and Efficacy of Iranian Recombinant FVIII (Safacto) versus Plasma Derived FVIII A pilot study
Background: Considering the increasing number of patients with hemophilia and infrastructure requirements for a comprehensive approach, development of a recombinant factor has become a milestone. The objective of this study was to assess the safety, efficacy and non inferiority of Safacto (Recombinant factor VIII) compared with plasma-derived factor in the treatment of hemophilia A. Methods: 10 ...
متن کاملTHE ROLE OF VARIOUS STABILIZERS IN THE ACQUISITION OF THERMO-TOLER ANCE IN FACTOR VIII ACTIVITY
We prepared a highly purified and relatively heat stable form of factor VIII which contained 25 units per mL (u/mL) activity using PEG-4000 and developed an effective and new manufacturing process. Heat treatment was performed at 80°C for 72 hrs in the presence of different stabilizers. In our studies, we used different organic solvents as preservatives to maintain factor VIII activity, sin...
متن کاملEffect of Cavity Dimentions with the Same C-Factor on Micro Leakage of Composite Resin Cavities
Abstract Background and aim: Given the prevalence of microleakage in composites and their known complications and lack of reporting of the influence of cavity depth and diameter on the same c-factor on the microleakage of composite cavities, this study investigated the effect of microleakage on composite cavities in identical C Factors. Materials and Methods: In this experimental study on 40 ...
متن کاملفراوانی هپاتیتB ، هپاتیتC و ارتباط آنها با ایجاد مهار کننده فاکتور VIII در مبتلایان هموفیلی استان همدان- 1383
Abstract: Background: Hemophilia is a x-linked deficiency of factor VIII. The aim of the present study was to determine the frequencies of hepatitis B and C infections, markers of inflammation and liver function tests and also to assess the possible association between factor VIII inhibitor and hepatitis B and C infections in hemophiliacs of Hamedan Province of Iran. Materials and methods: Si...
متن کاملCombined Factor V and VIII Deficiency
This review summarizes current data on the pathomechanisms and new genetic findings of combined factor V and VIII deficiency (CF5F8D). Congenital haemorrhagic disorders characterized by deficiency of two clotting factors comprise an interesting group. Among dual coagulation disorders, CF5F8D is the most common type. For the first time combined factor V and VIII deficiency (F5F8D) was reported b...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Journal of clinical pathology
دوره 35 3 شماره
صفحات -
تاریخ انتشار 1982