Simultaneous Monitoring of Temperature and Magnetization Transfer during HIFU Transmission: in vivo rabbit investigations
نویسندگان
چکیده
H-H. Peng, T-Y. Huang, H-W. Chung, S-Y. Ju, Y-H. Yang, P-C. Chen, Y-H. Ding, W-S. Chen, and W-Y. I. Tseng Department of Biomedical Engineering and Environmental Sciences, National Tsing Hua University, Hsinchu, Taiwan, Department of Electrical Engineering, National Taiwan University of Science and Technology, Taipei, Taiwan, Department of Electrical Engineering, National Taiwan University, Taipei, Taiwan, Department of Physical Medicine and Rehabilitation, National Taiwan University Hospital, Taipei, Taiwan, Center for Optoelectronic Biomedicine, Medical College of National Taiwan University, Taipei, Taiwan
منابع مشابه
Numerical Study for Optimizing Parameters of High-Intensity Focused Ultrasound-Induced Thermal Field during Liver Tumor Ablation: HIFU Simulator
Introduction High intensity focused ultrasound (HIFU) is considered a noninvasive and effective technique for tumor ablation. Frequency and acoustic power are the most effective parameters for temperature distribution and the extent of tissue damage. The aim of this study was to optimize the operating transducer parameters such as frequency and input power in order to acquire suitable temperatu...
متن کاملPotential enhancement of intravenous nano-hydroxyapatite in high-intensity focused ultrasound ablation for treating hepatocellular carcinoma in a rabbit model
The aim of the present study was to evaluate the safety and efficiency of an intravenously delivered nano-hydroxyapatite (Nano-HA) solution into a rabbit model (Oryctolagus cuniculus) to determine the potential enhancement of high-intensity focused ultrasound (HIFU) for the ablation of hepatocellular carcinoma (HCC) in liver tissue. The present study clearly indicated that the intravenous deliv...
متن کاملHigh intensity focused ultrasound (HIFU) focal spot localization using harmonic motion imaging (HMI).
Several ultrasound-based imaging modalities have been proposed for image guidance and monitoring of high-intensity focused ultrasound (HIFU) treatment. However, accurate localization and characterization of the effective region of treatment (focal spot) remain important obstacles in the clinical implementation of HIFU ablation. Harmonic motion imaging for focused ultrasound (HMIFU) is a HIFU mo...
متن کاملClinical validation of real-time tissue change monitoring during prostate tissue ablation with high intensity focused ultrasound
BACKGROUND The purpose of these clinical studies was to validate a Tissue Change Monitoring (TCM) algorithm in vivo. TCM is a quantitative tool for the real-time assessment of HIFU dose. TCM provides quantitative analysis of the backscatter pulse echo signals (pre and immediately post HIFU) for each individual ablative site, using ultrasonic tissue characterization as a surrogate for monitoring...
متن کاملSimulation of tissue heating by magnetic fluid hyperthermia
Objective: Magnetic fluid hyperthermia is a technique in which thermal energy is generated by magnetic nanoparticles (MNPs) that are excited by an alternating magnetic field (AC field). During hyperthermia, in-vivo monitoring of elevation of temperature relies on invasive insertion of conventional thermometers, or employment of thermo-sensitive cameras that lack high precision....