Evaluation of the manual enzyme immunoassay (EMIT) procedure for determination of serum thyroxine.
نویسندگان
چکیده
Our experience with the determination of thyroxine (T4) in serum using a homogeneous enzyme immunoassay technique (EMIT, Syva Corp.) is reported. The intra-assay precision of the EMIT Manual Thyroxine Assay was investigated with 2 different calibrator concentrations and showed coefficients of variation varying from 5--2% for thyroxine concentrations of 40 and 120 micrograms/l thyroxine respectively. The inter-assay precision was investigated with different series of calibrators and serum specimens. Coefficients of variation for the calibrators varied from 35--5% in the range of 20--200 micrograms/l thyroxine and for the serum specimens in the range of 8--232 micrograms/l thyroxine from 50--4%. The recovery of various amounts of thyroxine added to thyroxine-free serum varied between 91--103%. The cross reactivity of structurally related compounds such as: monoiodothyronine, diiodothyronine, triiodothyronine, triiodothyroacetic acid and tetraiodothyroacetic acid was investigated. Serum samples of 100 patients were analysed by EMIT and radioimmunoassay (T4 RIA (PEG), Abbott Lab.). A good correlation was found between the EMIT and RIA assay (r = 0.96, slope = 0.96 and y-intercept = 3.37 micrograms/l).
منابع مشابه
Evaluation of homogeneous enzyme immunoassay of serum thyroxine with the Gilford 3500 analyzer.
I evaluated homogeneous enzyme immunoassay (EMIT) of serum thyroxine with the Gilford 3500 analyzer. The samples are pretreated before quantitation on the Gilford 3500; the procedure thereafter is entirely mechanized. Forty-four samples may be analyzed per run. Precision and accuracy are good, and results correlate well with those by radioimmunoassay.
متن کاملHomogeneous enzyme immunoassay for thyroxine compared with a radioimmunoassay technique.
A homogeneous enzyme immunoassay (EMIT) for serum thyroxine determination has been evaluated. It was also compared to our routine method, a radioimmunoassay with use of a commercial kit, Tetra-Tab RIA. Within-day precision was very similar for the two methods, the CV ranging from about 2.5% at 150 nmol of thyroxine per liter to about 5.7% at 25 nmol/L. The two methods were compared by running 1...
متن کاملEvaluation of homogeneous enzyme immunoassay of serum thyroxine with use of bichromatic analysis.
We evaluated the homogeneous enzyme immunoassay ("EMIT") of serum thyroxine with use of an ABA- 100 Bichromatic Analyzer, modified with an auxiliary dispenser syringe and a dual probe assembly. The modification allows two reagents to be dispensed at one time. The sera must be pre-treated with 0.1 mol/liter NaOH. The procedure thereafter is entirely automated. Twenty-four patients' samples may b...
متن کاملDetermination of methotrexate in serum by a rapid, fully mechanized enzyme immunoassay (EMIT).
A homogeneous enzyme immunoassay for the determination of methotrexate in serum (EMIT, Syva Corp.) was fully mechanized by the use of an Eppendorf analyzer 5010. Coefficients of variation from day to day were in the range 2--16%. A comparison of the results obtained by EMIT and a radioimmunoassay (Methotrexate 125 I Radioimmunoassay Kit, Diagnostic Biochemistry Inc.) in a series of 50 samples f...
متن کاملDETERMINATION OF SERUM CORTISOL LEVEL BY A DIREC T ENZYME IMMUNOASSAY USING PENICILLINASE AS LABEL
Serum cortisol level was measured by an enzyme immunoassay (EIA) using the enzyme penicillinase as a label without prior extraction and purification. Polyclonal antibodies were raised against cortisol-3-ortho-carboxymethyl-oxime (cortisol-3-0-CMO) conjugated to bovine serum albumin (BSA). This antibody showed a very low cross-reactivity with structurally related steroids (3.7% for corticos...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of clinical chemistry and clinical biochemistry. Zeitschrift fur klinische Chemie und klinische Biochemie
دوره 17 5 شماره
صفحات -
تاریخ انتشار 1979