Defection of phalanx: a complication of Bunnell’s pulley reconstruction

نویسندگان

  • Chao Lu
  • Guanglei Tian
چکیده

Objective: To report defection of phalanx under the reconstructed pulleys with Bunnell’s technique. Methods: We followed up 26 reconstructed annular pulleys in 23 digits of 18 cases for 20 months and analysed the X-ray results of those phalanges. The function of pulley reconstruction was observed. The joint flexion and extension movement of the finger joint was recorded. Results: All the reconstructed pulleys were healed. The efficacy was good. No bowstringing sign was found. The defections of phalanx were found in the areas of reconstructed pulleys in all cases. Narrowing of medullary cavities, osteophyte formation and thinning of cortex of phalanges were found in some cases with X-ray examination. The joint flexion and extension movement of the finger joint has improved. Conclusion: Defection of phalanges will be found after Bunnell’s pulley reconstruction. It could be caused by pulley’s pressure which is converted from the traction load of the flexor tendon. Prognostic Studies, Level IV.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Impact of taping after finger flexor tendon pulley ruptures in rock climbers.

Flexor tendon pulley ruptures are the most common injury in rock climbers. Therapeutic standards usually include a prolonged use of taping applied as a replacement for the lost pulley in a circular fashion at the base of the proximal phalanx. Our biomechanical considerations, however, suggest a new taping method, the H-tape. The purpose of the study is to evaluate whether this new taping method...

متن کامل

Development of an Underactuated Finger Mechanism for a Hand Prosthesis

This works shows the conceptual development of a finger mechanism for a prothestic hand. Three degrees of freedom of the finger are actuated by single DC motor, characterizing therefore an underactuated mechanical system. Mechanical torque developed by the motor is transmitted to the phalanges through tendons and is converted into flexion and extension torques by means of small pulleys. The ten...

متن کامل

Finger injuries in extreme rock climbers. Assessment of high-resolution ultrasonography.

Dynamic high-resolution ultrasonography findings obtained in 34 extreme rock climbers with finger injuries were compared with those in 20 healthy volunteers. Thicknesses of the flexor tendon and A-2 flexor tendon pulley system were measured at the base of the proximal phalanx. The distance between the tendon and phalanx was evaluated with the finger in extension and in forced flexion as a measu...

متن کامل

Extra-articular avulsion fracture of the distal phalanx of the ring finger--a case report.

This report describes a rare case of extra-articular avulsion fracture of the flexor digitorum profundus tendon in a 59-year-old man is reported. A large avulsed fragment of bone was localized by radiography on the volar side of the middle phalanx. The avulsed bone fragment had torn the A4 pulley and had been caught by the C2 pulley. The fracture was extra-articular. The avulsed fragment was fi...

متن کامل

An unusual cause of A2 pulley rupture in a 49-year-old man.

A 49-year-old man presented to his family physician with pain in the third finger that occurred after he tried to grasp a falling heavy object. His finger was forcefully extended from a semi-flexed position. On clinical examination extension was normal. However, flexion was slightly limited and extremely painful at the end point of flexion. Ultrasound of the finger was performed and showed that...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2017