Visualization of stent lumen in MR imaging: relationship with stent design and RF direction.

نویسندگان

  • Seiichiro Ohno
  • Takashi Harimoto
  • Miyuki Hirose
  • Masahiro Miyai
  • Kengo Hattori
  • Masahiro Kuroda
  • Susumu Kanazawa
  • Keiji Inamura
  • Hirokazu Kato
چکیده

Magnetic resonance imaging (MRI) visualization of metallic stent lumens is possible if the stent structure counteracts eddy currents in the lumen induced by the radio frequency magnetic field, B(1). To examine the effectiveness of various stent designs in counteracting eddy currents, we anchored eight copper stent models and 2 commercially available nickel-titanium alloy (Nitinol) stents in a gel phantom, perpendicular or parallel to the direction of B(1). A mesh stent lumen showed hypointensity irrespective of its alignment relative to B(1). A solenoid stent lumen showed hypointensity with the stent axis parallel to B(1), but it had the same signal intensity as outside the lumen when perpendicular to B(1). A Moebius stent lumen showed no signal reduction, irrespective of alignment relative to B(1). Lumens of the commercially available stents showed hypointensity regardless of alignment relative to B(1). Computer simulation revealed that the signal intensities of the stents corresponded to magnetic flux densities of B(1) in the stents, which are modified by the structure of the stent. While in vivo MRI viewing of a Moebius stent lumen is likely possible regardless of axis alignment, inherent structural weakness may be problematic. As a more practical choice, the solenoid stent is easier to manufacture and generates no hypointensive signal when the axis is parallel to B(0).

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Optimal Stent Expansion by Stent Balloon Multiple Inflation at Nominal Pressure in Resistant Lesions: A New Technique

Introduction: This study aimed to evaluate the effects of four-time inflation of the stent balloon at nominal pressure on optimal stent expansion in resistant lesions. Materials and Methods: This interventional study was conducted on 39 patients with coronary artery lesions, in whom Zotarolimus-eluting stents (N=20), Paclitaxel-eluting stents (N=11) and other stents (N=8) were deployed four tim...

متن کامل

Artifact-free in-stent lumen visualization by standard magnetic resonance angiography using a new metallic magnetic resonance imaging stent.

BACKGROUND Metallic stents cause susceptibility and radiofrequency artifacts on MR images, which, up to now, have not allowed for complete visualization of the stent lumen by MR angiography. The aim of this study was to investigate the potential of a new dedicated renal MRI stent for artifact-free in-stent lumen visualization in vitro and in a swine model. METHODS AND RESULTS In vitro investi...

متن کامل

Inductively coupled stent antennas in MRI.

The development of intimal hyperplasia following stent deployment can lead to narrowing or even occlusion of the stent lumen. The underlying mechanisms leading to neointimal proliferation within stents remain largely unknown. Long-term evaluation of stent patency requires a noninvasive means for assessing the stent lumen. MR angiography (MRA) has shown potential to provide noninvasive assessmen...

متن کامل

Vascular stents as RF antennas for intravascular MR guidance and imaging.

Stent deployment is used to improve the immediate and long-term results of vascular interventions in various vascular sites. X-ray angiography as an imaging modality is often limited in providing an accurate assessment with regard to vessel size, plaque calcification, or stent deployment. In this study, the potential of using the stent endoprothesis as a radiofrequency (RF) receive-only probe f...

متن کامل

Artifact-free coronary magnetic resonance angiography and coronary vessel wall imaging in the presence of a new, metallic, coronary magnetic resonance imaging stent.

BACKGROUND Coronary in-stent restenosis cannot be directly assessed by magnetic resonance angiography (MRA) because of the local signal void of currently used stainless steel stents. The aim of this study was to investigate the potential of a new, dedicated, coronary MR imaging (MRI) stent for artifact-free, coronary MRA and in-stent lumen and vessel wall visualization. METHODS AND RESULTS Fi...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Acta medica Okayama

دوره 66 3  شماره 

صفحات  -

تاریخ انتشار 2012