High Count Rate Electron Probe Microanalysis

نویسندگان

  • Joseph D. Geller
  • Charles Herrington
چکیده

Reducing the measurement uncertainty of quantitative analyses made using electron probe microanalyzers (EPMA) requires a careful study of the individual uncertainties from each definable step of the measurement. Those steps include measuring the incident electron beam current and voltage, knowing the angle between the electron beam and the sample (takeoff angle), collecting the emitted x rays from the sample, comparing the emitted x-ray flux to known standards (to determine the k-ratio) and transformation of the k-ratio to concentration using algorithms which includes, as a minimum, the atomic number, absorption, and fluorescence corrections. This paper discusses the collection and counting of the emitted x rays, which are diffracted into the gas flow or sealed proportional x-ray detectors. The representation of the uncertainty in the number of collected x rays collected reduces as the number of counts increase. The uncertainty of the collected signal is fully described by Poisson statistics. Increasing the number of x rays collected involves either counting longer or at a higher counting rate. Counting longer means the analysis time increases and may become excessive to get to the desired uncertainty. Instrument drift also becomes an issue. Counting at higher rates has its limitations, which are a function of the detector physics and the detecting electronics. Since the beginning of EPMA analysis, analog electronics have been used to amplify and discriminate the x-ray induced ionizations within the proportional counter. This paper will discuss the use of digital electronics for this purpose. These electronics are similar to that used for energy dispersive analysis of x rays with either Si(Li) or Ge(Li) detectors except that the shaping time constants are much smaller.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

In Situ Analysis of Gut Residue of Corophium Volutator (Pallas) by Electron Probe Microanalysis after Exposure to Barytes Spiked Sediments

Corophium volutator (Pallas) has been recommended by the paris Commission as one of the standard species for testing chemical used in offshore oil and gas exploration/production. In the present study, gut contents of Corophium volutator have been analysed by electron probe microanalysis (EPMA) for BaSO4 and other heavy metal impurities after exposure tto spiked sediments followin...

متن کامل

Prospects for Trace Analysis in the Analytical Electron-Microscope

The analytical electron microscope (AEM) uses a high energy (>100 kV) beam of electrons to generate a range of signals from a thin foil sample as shown in figure la [1,2]. Various detectors are configured in the AEM to pick up most of the generated signals (fig. lb). Microanalysis is usually performed using the characteristic x-ray signal, detected by an energy dispersive spectrometer (EDS) alt...

متن کامل

Electron probe microanalysis: principles and applications

This article summarizes the basic principles of electron probe microanalysis, with examples of applications in materials science and geology that illustrate the capabilities of the technique. Handbook of instrumental techniques from CCiTUB Electron probe microanalysis

متن کامل

Liquation Cracking of Dissimilar Aluminum Alloys during Friction Stir Welding

A liquation cracking mechanism of dissimilar Al alloys during the friction stir welding (FSW) is suggested in this study. To identify the mechanism, the precipitates were analyzed and Al-Mg-Cu phase diagrams were calculated. Electron backscattering diffraction (EBSD) analysis and electron probe microanalysis (EPMA) were also conducted. In the same manner as constitutional liquation, at high hea...

متن کامل

New constraints on electron-beam induced halogen migration in apatite

Fluorine and chlorine X‐ray count rates are known to vary significantly during electron probe microanalysis (EPMA) of apatite. Since the rate, timing, and magnitude of this variation are a function of apatite orientation and composition, as well as EPMA operating conditions, this represents a significant problem for volatile element analysis in apatite. Although the effect is thought to be an i...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 107  شماره 

صفحات  -

تاریخ انتشار 2002