Method of inserting the Smith-Petersen guide wire.

نویسنده

  • J CHARNLEY
چکیده

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Treatment of Fractures of Neck of Femur

1. The proper use of a Smith-Petersen nail is the best method of treating intracapsular fractures of the neck of the femur. Its simplicity and accuracy represent a great advance over older methods. 2. The Smith-Petersen nail is only the provision of an efficient internal splint. Its great merit is that it allows the patient to get up within a few days. 3. The Smith-Petersen nail will neither en...

متن کامل

Effect of Inserting Coiled Wires in Tubes on the Fluid Flow and Heat Transfer Performance of Nanofluids

In the present study, numerical study of Al2O3-water nanofluid flow in different coiled wire inserted tubes are performed to investigate the effects of inserting coiled wires in tubes on the fluid dynamic and heat transfer performance ofv nanofluids. The numerical simulations of nanofluids are performed using two phase mixture model. The flow regime and the wall boundary conditions are assumed ...

متن کامل

حل مشکل جاگذاری کاتتر ورید مرکزی با استفاده از کاتتر وریدی: مقاله تکنیکال

Insertion of central venous catheter is an accepted method for hemodynamic monitor-ring, drug and fluid administration, intravenous access, hemodialysis and applying cardiac pace-maker in hospitalized patients. This procedure can be associated with severe complications. The aim of this article is to provide a practical approach to prevent catheter malposition in states that the guide wire will ...

متن کامل

Intrapelvic Protrusion of a Broken Guide Wire Fragment during Fixation of a Femoral Neck Fracture

  During fixation of a femoral neck fracture in a 23-year-old male patient with cannulated screws, a broken guide wire fragment inadvertently advanced through the hip joint and protruded into the pelvis. A second surgical approach was needed to remove the broken fragment from the pelvis. Awareness of such a potentially devastating complication will make surgeons more cautious during implementa...

متن کامل

Evaluation of guide wire cannulation in reduced risk of post - ERCP pancreatitis and facilitated bile duct cannulation

Background: Pancreatitis is most common complication of post-ERCP and needs to admission at least for one day. The purpose of this study was to assess the efficacy of guide wire for better common bile duct (CBD) cannulation for reducing post-ERCP pancreatitis. Methods: From April 2010 through March 2011, the patients who needed ERCP and referred to Shahid Beheshti and Rouhani Teaching Hospita...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Journal of bone and joint surgery. British volume

دوره 32-B 2  شماره 

صفحات  -

تاریخ انتشار 1950