The Gray Filtration on Phantom Maps
نویسنده
چکیده
This paper is a study of the Gray index of phantom maps. We give a new, tower theoretic, definition of the Gray index, which allows us to study the naturality properties of the Gray index in some detail. McGibbon and Roitberg have shown that if f∗ is surjective on rational cohomology, then the induced map on phantom sets is also surjective. We show that if f ∗ is surjective just in dimension k, then f induces a surjection on a certain subquotient of the phantom set. If the condition holds for all k, we recover McGibbon and Roitberg’s theorem. There is a dual result, and a theorem on phantom maps into spheres which holds one dimension at a time as well. Finally, we examine the set of phantom maps whose Gray index is infinite. The main theorem is a partial verification of our conjecture that if X and Y are nilpotent and of finite type, then every phantom map f : X −→Y must have finite index. Math. Subject Classifications: 55S37, 55P30, 55P62, 20G10, 20J05
منابع مشابه
Sensitivity Encoded Proton Echo Planar Spectroscopic Imaging (PEPSI) in Human Brain at 7 Tesla
choline, glutamate and inositol (32x32 matrix) with 2-fold SENSE acceleration. Fig.3 Fully sampled PEPSI maps of non-suppressed water (64x64 matrix) and metabolite maps of NAA, creatine, choline, glutamate and inositol (32x32 matrix), acquired in 8.5 min with 0.63 cc voxel size. Fig.1 Non-water-suppressed PEPSI maps on phantom at 7 T show good reconstruction performance for up to 4-fold acceler...
متن کاملGray Images of Constacyclic Codes over some Polynomial Residue Rings
Let be the quotient ring where is the finite field of size and is a positive integer. A Gray map of length over is a special map from to ( . The Gray map is said to be a ( )-Gray map if the image of any -constacyclic code over is a -constacyclic code over the field . In this paper we investigate the existence of ( )-Gray maps over . In this direction, we find an equivalent ...
متن کاملA 4D CT digital phantom of an individual human brain for perfusion analysis
Brain perfusion is of key importance to assess brain function. Modern CT scanners can acquire perfusion maps of the cerebral parenchyma in vivo at submillimeter resolution. These perfusion maps give insights into the hemodynamics of the cerebral parenchyma and are critical for example for treatment decisions in acute stroke. However, the relations between acquisition parameters, tissue attenuat...
متن کاملEvaluation of the gray level in CBCT systems and its relationship with HU in CT Scanners
Introduction: Cone-beam CT (CBCT) is an imaging system which offers three-dimensional (3D), multiplanar images and has many advantages over computed tomography (CT) including shorter acquisition times for the resolution desired in dentistry, lower radiation dose to the patient, reasonable price and higher spatial resolution but CBCT scanners are unable to display actual Hounsf...
متن کاملAnalysis of the reproducibility of the gray values and noise of a direct digital radiography system.
The aim of this study was to evaluate the reproducibility of the gray values and noise of a direct digital radiography system (Visualix eHD) for various exposure times and analyzed regions. To obtain radiographic images in a standardized manner, the digital sensor of the system and a stepwedge were positioned in a phantom at a focus-film distance of 30 cm in a dental device at 70 kV, 7 mA and 2...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -